Chemiluminometric method for the determination of glycerol in wine by flow-injection analysis with co-immobilized glycerol dehydrogenase NADH oxidase

被引:20
作者
Kiba, N
Azuma, N
Furusawa, M
机构
[1] Dept. of Appl. Chem. and Biotech., Faculty of Engineering, Yamanashi University
关键词
chemiluminescence; enzyme reactor; flow injection; glycerol; wine;
D O I
10.1016/0039-9140(96)01969-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection method for the determination of glycerol in wine is described. Glycerol dehydrogenase and NADH oxidase were co-immobilized on poly (vinyl alcohol) beads and incorporated in a flow-injection system. The hydrogen peroxide produced was detected chemiluminometrically via a luminol-hexacyanoferrate (III) reaction. Wine was diluted 1000-fold with water and sample solution (50 mu l) was injected into the carrier stream. The calibration graph was linear in the range 3 x 10(-7)-3 x 10(-4) M; the detection limit was 7 x 10(-8) M and the sample throughout was 30 h(-1) without carryover.
引用
收藏
页码:1761 / 1766
页数:6
相关论文
共 14 条
[1]   SULFITE-BINDING POWER OF WINES AND CIDERS .1. EQUILIBRIUM CONSTANTS FOR DISSOCIATION OF CARBONYL BISULFITE COMPOUNDS [J].
BURROUGHS, LF ;
SPARKS, AH .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1973, 24 (02) :187-198
[2]   GLYCEROL DEHYDROGENASE FROM AEROBACTOR-AEROGENES [J].
BURTON, RM .
METHODS IN ENZYMOLOGY, 1955, 1 :397-400
[3]   DETERMINATION OF L-MALATE IN WINE BY FLOW-INJECTION WITH CO-IMMOBILIZED MALATE-DEHYDROGENASE OXALOACETATE DECARBOXYLASE [J].
KIBA, N ;
OGUCHI, M ;
FURUSAWA, M .
TALANTA, 1993, 40 (08) :1163-1165
[4]  
KIBA N, 1996, TALANTA, V42, P1751
[5]   A NEW CHEMILUMINOMETRIC METHOD FOR THE DETERMINATION OF GLYCEROL IN WINE BY FLOW-INJECTION ANALYSTS WITH IMMOBILIZED GLYCEROL DEHYDROGENASE IN COMBINATION WITH NADH OXIDASE [J].
KONDRUWEIT, S ;
DREMEL, BAA ;
SCHMID, RD .
ANALYTICAL LETTERS, 1994, 27 (08) :1489-1505
[6]   CONTINUOUS-FLOW CHEMILUMINESCENCE DETECTION COMPRISING A ROTATING REACTOR [J].
LAN, ZH ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :139-146
[7]   FLOW-INJECTION ASSAYS WITH CHEMILUMINESCENCE AND BIOLUMINESCENCE DETECTION - A REVIEW [J].
LEWIS, SW ;
PRICE, D ;
WORSFOLD, PJ .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1993, 8 (04) :183-199
[8]   DETERMINATION OF GLYCEROL IN WINE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH AN IMMOBILIZED GLYCEROL DEHYDROGENASE REACTOR [J].
MATSUMOTO, K ;
MATSUBARA, H ;
HAMADA, M ;
DOI, T ;
OSAJIMA, Y .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1991, 55 (04) :1055-1059
[9]  
MATSUMOTO K, 1991, J JPN SOC FOOD SCI, V38, P699
[10]  
PLUEDDEMANN EP, 1982, SILANE COUPLING AGEN, P227