Uricase purified from 20-day-old leaves of cowpea was immobilized on to epoxy resin membrane with 80% retention of initial activity of free enzyme and a conjugation yield of 0.056 mg/cm(2). The uricase epoxy resin bioconjugate membrane was mounted over the sensing part of the combined electrode of 'Aqualytic' dissolved O-2. (DO) meter to construct a uric acid biosensor. The biosensor measures the depletion of dissolved O-2 during the oxidation of uric acid by immobilized uricase, which is directly proportional to uric acid concentration. The biosensor showed optimum response within 10-12 s at a pH 8.5 and 35 degrees C. A linear relationship was found between uric acid concentration from 0.025 to 0.1 mM and O-2 (mg/l) consumed. The biosensor was employed for measurement of uric acid in serum. The mean value of uric acid in serum was 4.92 mg/dl in apparently healthy males and 3.11 mg/dl in apparently healthy females. The mean analytic recoveries of added uric acid in reaction mixture (8.9 and 9.8 mg/dl) were 93.6 +/- 2.34 and 87.18 +/- 3.17% respectively. The within and between batch CVs were <6.5 and <5.0%, respectively. The serum uric acid values obtained by present method and standard enzymic colorimetric method, showed a good correlation (r = 0.996) and regression equation being y = 0.984x + 0.0674. Among the various metabolites tested only, glucose (11%). urea (38%), NaCl (25%) and cholesterol (13%) and ascorbic acid (56%) caused decrease, while, MgSO4 and CaCl2 had no effect on immobilized enzyme. The enzyme electrode showed only 32% decrease during its use for 100 times over a period of 60 days at 4 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 40 条
[1]   Determination of uric acid by voltammetry and coulometric titration [J].
Abdullin, IF ;
Bakanina, YN ;
Turova, EN ;
Budnikov, GK .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (05) :453-456
[2]   A biosensor based on urate oxidase-peroxidase coupled enzyme system for uric acid determination in urine [J].
Akyilmaz, E ;
Sezgintürk, MK ;
Dinçkaya, E .
TALANTA, 2003, 61 (02) :73-79
[3]   Improved performance of polyaniline-uricase biosensor [J].
Arora, Kavita ;
Sumana, G. ;
Saxena, Vibha ;
Gupta, R. K. ;
Gupta, S. K. ;
Yakhmi, J. V. ;
Pandey, M. K. ;
Chand, Subhash ;
Malhotra, B. D. .
ANALYTICA CHIMICA ACTA, 2007, 594 (01) :17-23
[4]   An amperometric biosensor for uric acid determination prepared from uricase immobilized in polyaniline-polypyrrole film [J].
Arslan, Fatma .
SENSORS, 2008, 8 (09) :5492-5500
[5]   Discrete analysis of serum uric acid with immobilized uricase and peroxidase [J].
Bhargava, AK ;
Lal, H ;
Pundir, CS .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1999, 39 (03) :125-136
[6]   Immobilization of uricase upon polypyrrole-ferrocenium film [J].
Cete, Servet ;
Yasar, Ahmet ;
Arslan, Fatma .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2007, 35 (06) :607-620
[7]   An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film [J].
Cete, Servet ;
Yasar, Ahmet ;
Arslan, Fatma .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (03) :367-380
[8]  
CHEN ZC, 2006, CONTINUOUS DISCRETE, P2038
[9]  
DILENA BA, 1986, CLIN CHEM, V32, P486
[10]   Direct determination of uric acid in serum by a fluorometric-enzymatic method based on uricase [J].
Galbán, J ;
Andreu, Y ;
Almenara, MJ ;
de Marcos, S ;
Castillo, JR .
TALANTA, 2001, 54 (05) :847-854