Atomic force microscope detector drift compensation by correlation of similar traces acquired at different setpoints

被引:24
作者
Kindt, JH [1 ]
Thompson, JB [1 ]
Viani, MB [1 ]
Hansma, PK [1 ]
机构
[1] Univ Calif Santa Barbara, Dept Phys, Santa Barbara, CA 93103 USA
关键词
D O I
10.1063/1.1475352
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
The atomic force microscope measures surface topography by maintaining a certain cantilever deflection or vibration amplitude as the cantilever is scanned over a sample surface. The desired cantilever deflection or amplitude is referred to as the setpoint, and is maintained by moving the sample toward or away from the cantilever. The signal from the cantilever deflection detector has a real component, due to cantilever deflection, and a drift component due to various sources of drift. We present a method of eliminating the drift component by sensing and correcting it in real time. Our method involves automatically changing the setpoint so as to maintain a certain set difference in the relative feature richness of two traces taken with slightly offset setpoints. We show how the system maintains a setpoint only 70 mV above minimum, perturb it with a gentle blow of air that causes 200 mV of detector drift, and observe its recovery within 13+-6 s. (C) 2002 American Institute of Physics.
引用
收藏
页码:2305 / 2307
页数:3
相关论文
共 19 条
[1]
AN ATOMIC-RESOLUTION ATOMIC-FORCE MICROSCOPE IMPLEMENTED USING AN OPTICAL-LEVER [J].
ALEXANDER, S ;
HELLEMANS, L ;
MARTI, O ;
SCHNEIR, J ;
ELINGS, V ;
HANSMA, PK ;
LONGMIRE, M ;
GURLEY, J .
JOURNAL OF APPLIED PHYSICS, 1989, 65 (01) :164-167
[2]
Multiple sensor stabilization system for local probe microscopes [J].
Altmann, SM ;
Lenne, PF ;
Hörber, JKH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :142-149
[3]
ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[4]
ATOMIC SCALE FRICTION BETWEEN THE MUSCOVITE MICA CLEAVAGE PLANE AND A TUNGSTEN TIP [J].
ERLANDSSON, R ;
HADZIIOANNOU, G ;
MATE, CM ;
MCCLELLAND, GM ;
CHIANG, S .
JOURNAL OF CHEMICAL PHYSICS, 1988, 89 (08) :5190-5193
[5]
FORTIADIS D, 1999, BIOPHYS J, V76, P1101
[6]
GODDENHENRICH T, 1990, J VAC SCI TECHNOL A, V8, P383, DOI 10.1116/1.576401
[7]
A HIGH-STABILITY AND LOW DRIFT ATOMIC FORCE MICROSCOPE [J].
HUG, HJ ;
JUNG, T ;
GUNTHERODT, HJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08) :3900-3904
[8]
MAGNETIC IMAGING BY FORCE MICROSCOPY WITH 1000-A RESOLUTION [J].
MARTIN, Y ;
WICKRAMASINGHE, HK .
APPLIED PHYSICS LETTERS, 1987, 50 (20) :1455-1457
[9]
COMPARATIVE-STUDY OF LITHIUM-FLUORIDE AND GRAPHITE BY ATOMIC FORCE MICROSCOPY (AFM) [J].
MEYER, E ;
HEINZELMANN, H ;
GRUTTER, P ;
JUNG, T ;
WEISSKOPF, T ;
HIDBER, HR ;
LAPKA, R ;
RUDIN, H ;
GUNTHERODT, HJ .
JOURNAL OF MICROSCOPY-OXFORD, 1988, 152 :269-280
[10]
CORRECTION [J].
MEYER, G .
APPLIED PHYSICS LETTERS, 1988, 53 (24) :2400-2400