A novel spectrophotometric method for batch and flow injection determination of sulfite in beverages

被引:98
作者
Hassan, Saad S. M. [1 ]
Hamza, Mohamed S. A. [1 ]
Mohamed, Ayman H. K. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
spectrophotometry; diaquacobyrinic acid heptamethylester (daquacobester); sulfite determination; flow injection analysis; beverages;
D O I
10.1016/j.aca.2006.04.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel spectrophotometric assay method for batch and flow injection determination of sulfite in beverages is described. The method involves a reaction with diaquacobyrinic acid heptamethyl ester (diaquacobester, DACbs) in acetate buffer of pH 3 to form a highly stable sulfite cobester complex (SO(3)Cbs). In the absence of sulfite, the reagent displays three absorption maxima at 349, 409 and 525 nm. Addition of sulfite is associated with the development of a new absorption band at 313 nm, an increase in the intensity of the band at 425 nm and a decrease in the absorbance of the bands at 349 and 525 nm. Variations of the absorptions at 313, 349, 425 and 525 nm are linearly proportional to sulfite concentrations over the range of 0.05-25 mu g ml(-1) with a detection limit of 0.01-0.2 mu g ml(-1). Negligible interferences are caused by most common ions. Validation of the method according to the quality assurance standards shows suitability for quality control assessment of sulfite in complex matrices without prior treatment. The method has the advantages of high selectivity, good sensitivity, fast reaction, high stability of the reagent and reaction product and absorbance measurements at four different wavelengths in the same run. The method is successfully applied to determine the sulfite contents of some beverages. The results compare fairly well with data obtained using the standard method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 42 条
[21]   Flow injection analysis of sulfite ion with a potentiometric titanium phosphate-epoxy based membrane sensor [J].
Hassan, SSM ;
Marei, SA ;
Badr, IH ;
Arida, HA .
TALANTA, 2001, 54 (04) :773-782
[22]   Chemiluminescence of sulfite based on auto-oxidation sensitized by rhodamine 6G [J].
Huang, YM ;
Zhang, C ;
Zhang, XR ;
Zhang, ZJ .
ANALYTICA CHIMICA ACTA, 1999, 391 (01) :95-100
[23]  
Irving H.M.N.H., 1981, IUPAC Compendium of Analytical Nomenclature: Definitive rules
[24]   Polymeric ISE for hydrogen sulfite based on bis-urea calix[4]diquinones as neutral lipophilic ionophores [J].
Jeon, SW ;
Yeo, HY ;
Jeong, HS ;
Oh, JM ;
Nam, KC .
ELECTROANALYSIS, 2003, 15 (10) :872-877
[25]  
LAWRENCE JF, 1988, J ASSOC OFF ANA CHEM, V71, P930
[26]   Ruthenium(II) tris(bipyridyl) ion as a luminescent probe for oxygen uptake on the catalyzed oxidation of HSO3- [J].
Lima, S ;
Bonifácio, RL ;
Azzellini, GC ;
Coichev, N .
TALANTA, 2002, 56 (03) :547-556
[27]   THE CHEMISTRY OF VITAMIN-B12 .28. CRYSTAL-STRUCTURE OF DICYANOCOBYRINIC ACID HEPTAMETHYL ESTER AND ITS INTERACTION WITH ALCOHOL - THE EFFECTS OF HYDROGEN-BONDING TO COORDINATED CYANIDE [J].
MARKWELL, AJ ;
PRATT, JM ;
SHAIKJEE, MS ;
TOERIEN, JG .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1987, (06) :1349-1357
[28]   HYDROPHOBIC VITAMIN-B12 .3. INCORPORATION OF HYDROPHOBIC VITAMIN-B12 DERIVATIVES INTO SINGLE-COMPARTMENT VESICLES AND THEIR ALKYLATION IN VARIOUS MOLECULAR AGGREGATES [J].
MURAKAMI, Y ;
HISAEDA, Y ;
OHNO, T .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1984, 57 (08) :2091-2097
[29]   HYDROPHOBIC VITAMIN-B-12 .12. PREPARATION, CHARACTERIZATION AND ENANTIOSELECTIVE ALKYLATION OF STRAPPED HYDROPHOBIC VITAMIN-B-12 [J].
MURAKAMI, Y ;
HISAEDA, Y ;
OHNO, T ;
KOHNO, H ;
NISHIOKA, T .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1995, (06) :1175-1183
[30]   Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film - Application to the analysis of some real samples [J].
Pournaghi-Azar, MH ;
Hydarpour, M ;
Dastangoo, H .
ANALYTICA CHIMICA ACTA, 2003, 497 (1-2) :133-141