Electrocatalytic tetracycline oxidation at a mixed-valent ruthenium oxide-ruthenium cyanide-modified glassy carbon electrode and determination of tetracyclines by liquid chromatography with electrochemical detection

被引:32
作者
Loetanantawong, B
Suracheep, C
Somasundrum, M
Surareungchai, W
机构
[1] King Mongkuts Univ Technol, Sch Bioresources & Technol, Bangkok 10150, Thailand
[2] King Mongkuts Univ Technol, PDTI, Bangkok 10150, Thailand
关键词
D O I
10.1021/ac035085b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-valent films of ruthenium oxide-ruthenium Cyanide were electrodeposited onto glassy carbon and characterized for the electrocatalytic oxidation of tetracycline. The currents produced by tetracycline were higher than from previously reported electrode modifications or pretreatments. In H2SO4 pH 1.0 + 0.5 M K2SO4, the second-order rate constant for the reaction between tetracycline and the Ru(III/IV) couple of ruthenium oxide was 3 x 10(5) +/- 1 x 10(5) mol(-1) cm(3) s(-1), and the rate of charge diffusion through the films was 4.5 x 10(-7) +/- 3.5 x 10(-7) cm(2) s(-1). Reaction was localized at the film-solution interface. When used as detectors in liquid chromatography (in H3PO4 pH 2.5 + 0.1 M KH2PO4 + 20% CH3CN, E = 1.10 V vs SCE), the electrodes gave limits of detection (>3 S/N) of 0.1 ppm for tetracycline and oxytetracycline and 0.5 ppm for doxycycline and chlorotetracycline. These limits were suitable for FDA and Codex Alimentarius guidelines for tetracyclines in food. Recoveries of the four tetracyclines from sea and freshwater shrimp were in the range 73-111%, which was higher or similar to the previously reported recoveries from shrimp.
引用
收藏
页码:2266 / 2272
页数:7
相关论文
共 41 条
[1]   Voltametric and flow injection determination of oxytetracycline residues in food samples using carbon fiber microelectrodes [J].
Agüí, L ;
Guzman, A ;
Pedrero, M ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ELECTROANALYSIS, 2003, 15 (07) :601-607
[2]   CATALYSIS OF ELECTROCHEMICAL REACTIONS AT REDOX POLYMER ELECTRODES - KINETIC-MODEL FOR STATIONARY VOLTAMMETRIC TECHNIQUES [J].
ANDRIEUX, CP ;
DUMASBOUCHIAT, JM ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 131 (JAN) :1-35
[3]  
ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
[4]   KINETICS OF ELECTROCHEMICAL REACTIONS MEDIATED BY REDOX POLYMER-FILMS - NEW FORMULATION AND STRATEGIES FOR ANALYSIS AND OPTIMIZATION [J].
ANDRIEUX, CP ;
DUMASBOUCHIAT, JM ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 169 (1-2) :9-21
[5]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[6]  
Botsoglou N. A., 1992, Food analysis by HPLC., P457
[7]   THE IMPORTANCE OF REACTIVE SURFACE GROUPS WITH REGARD TO THE ELECTROCATALYTIC BEHAVIOR OF OXIDE (ESPECIALLY RUO2) ANODES [J].
BURKE, LD ;
HEALY, JF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 124 (1-2) :327-332
[8]   Confirmation of multiple tetracycline residues in milk and oxytetracycline in shrimp by liquid chromatography particle beam mass spectrometry [J].
Carson, MC ;
Ngoh, MA ;
Hadley, SW .
JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2) :113-128
[9]   Sensitive determination of ethanol in low-alcohol samples by ion-exclusion chromatography with EC detection using a ruthenium-based inorganic film electrode [J].
Cataldi, TRI ;
Centonze, D ;
Desimoni, E .
FOOD CHEMISTRY, 1996, 55 (01) :17-21
[10]   ELECTROCATALYTIC OXIDATION AND AMPEROMETRIC DETECTION OF ALIPHATIC AND FURANIC ALDEHYDES AT A MIXED-VALENT RUTHENIUM OXIDE RUTHENIUM CYANIDE FILM ON GLASSY-CARBON ELECTRODES [J].
CATALDI, TRI ;
CAMPA, C ;
CENTONZE, D .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3740-3745