Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography

被引:42
作者
Li, Qi [1 ]
Lv, Fajin [2 ]
Li, Yongmei [2 ]
Li, Kewei [1 ]
Luo, Tianyou [2 ]
Xie, Peng [1 ]
机构
[1] Chongqing Med Univ, Dept Neurol, Affiliated Hosp 1, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Dept Radiol, Affiliated Hosp 1, Chongqing 400016, Peoples R China
关键词
Computed tomography angiography; Subarachnoid haemorrhage; Intracranial aneurysm; Digital subtraction angiography; COMPUTERIZED-TOMOGRAPHY ANGIOGRAPHY; 3D ROTATIONAL ANGIOGRAPHY; MASK BONE ELIMINATION; DIGITAL-SUBTRACTION; SUBARACHNOID HEMORRHAGE; CEREBRAL ANEURYSMS; DIAGNOSIS; METAANALYSIS; FEASIBILITY; VESSELS;
D O I
10.1007/s00330-009-1416-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to compare the diagnostic performance of subtraction computed tomography angiography (CTA) with conventional nonsubtracted CTA and digital subtraction angiography (DSA) for the detection of intracranial aneurysms. A total of 76 patients underwent both subtraction CTA and conventional CTA for the detection and therapy planning of suspected intracranial aneurysms. Subtraction and conventional CTA images were independently assessed by two readers in a blinded manner. The possibility of endovascular treatment or surgical clipping was also assessed based on information provided by CT angiograms alone. In 64 patients, 75 aneurysms were present on DSA. On a per-aneurysm basis, the sensitivity of subtraction CTA was 98.6% for reader 1, and 100% for reader 2. However, sensitivity of conventional CTA was 94.6% for reader 1, and 93.3% for reader 2. Therapeutic decisions could be made regarding 63 patients based on information provided by subtraction CTA images. However, conventional CTA provided sufficient information to make this decision for 55 patients. Conventional CTA has limited sensitivity in detecting very small aneurysms as well as aneurysms adjacent to bone. Subtraction CTA performed on a 64-row multidetector CT is an accurate and promising diagnostic tool that seems to be equivalent to 2D DSA for the detection and pretreatment planning of intracranial aneurysms.
引用
收藏
页码:2261 / 2267
页数:7
相关论文
共 28 条
[21]   Current diagnostic approaches to subarachnoid haemorrhage [J].
U-King-Im, JM ;
Koo, B ;
Trivedi, RA ;
Higgins, NJ ;
Tay, KY ;
Cross, JJ ;
Antoun, NM ;
Gillard, JH .
EUROPEAN RADIOLOGY, 2005, 15 (06) :1135-1147
[22]   Computerized tomography angiography in patients with subarachnoid hemorrhage: from aneurysm detection to treatment without conventional angiography [J].
Velthuis, BK ;
van Leeuwen, MS ;
Witkamp, TD ;
Ramos, LMP ;
van der Sprenkel, JMB ;
Rinkel, GJE .
JOURNAL OF NEUROSURGERY, 1999, 91 (05) :761-767
[23]   CT angiography of the circle of willis and intracranial internal carotid arteries: Maximum intensity projection with matched mask bone elimination-feasibility study [J].
Venema, HW ;
Hulsmans, FJH ;
den Heeten, GJ .
RADIOLOGY, 2001, 218 (03) :893-898
[24]   Aneurysms of the posterior circulation:: detection and treatment planning using volume-rendered three-dimensional helical computerized tomography angiography [J].
Villablanca, JP ;
Achiriolaie, A ;
Hooshi, P ;
Martin, N ;
Duckwiler, G ;
Jahan, R ;
Frazee, J ;
Gobin, P ;
Sayre, J ;
Viñuela, F .
JOURNAL OF NEUROSURGERY, 2005, 103 (06) :1018-1029
[25]   Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography [J].
Watanabe, Yoshiyuki ;
Uotani, Kensuke ;
Nakazawa, Tetsuro ;
Higashi, Masahiro ;
Yamada, Naoaki ;
Hori, Yoshiro ;
Kanzaki, Suzu ;
Fukuda, Tetsuya ;
Itoh, Toshihide ;
Naito, Hiroaki .
EUROPEAN RADIOLOGY, 2009, 19 (04) :1019-1024
[26]   Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review [J].
White, PM ;
Wardlaw, JM ;
Easton, V .
RADIOLOGY, 2000, 217 (02) :361-370
[27]   Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography [J].
Wintermark, M ;
Uske, A ;
Chalaron, M ;
Regli, L ;
Maeder, P ;
Meuli, R ;
Schnyder, P ;
Binaghi, S .
JOURNAL OF NEUROSURGERY, 2003, 98 (04) :828-836
[28]   Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography [J].
Young, N ;
Dorsch, NWC ;
Kingston, RJ ;
Markson, G ;
McMahon, J .
EUROPEAN RADIOLOGY, 2001, 11 (01) :123-130