Design of lanthanide complex probes for highly sensitive time-resolved fluorometric detection methods and its application to biochemical, environmental and clinical analyses

被引:16
作者
Matsuya, Takeshi
Hoshino, Nobuhiro
Okuyama, Tsuneo
机构
[1] Mitsubishi Kagaku Iatron Inc, Dept Res & Dev, Yachiyo, Chiba 2760046, Japan
[2] Prot Technos Inst, Kanagawa 2430206, Japan
关键词
lanthanide complex; fluorescent label; time-resolved fluorescence; high-performance liquid chromatography; immunoassay; electrophoresis;
D O I
10.2174/157341106778520526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lanthanide complexes have been used for fluorescent labels to the wide variety of analytical methods including high performance liquid chromatography, immunoassay, and fluorescent imaging with time-resolved fluorometric measurements. Introduction of a time-resolved fluorometric measurement has been permitted the easy distinction of a specific long-lived fluorescence signal from short-lived natural background fluorescence present in most biological samples, reaction wells and optical components. Recently, new fluorescent labels and new instruments have been reported for time-resolved fluorescence including high performance liquid chromatography as in environmental analysis as river water, clinical chemistry as allergen assay, and a biochemical analysis as in staining method of proteins on polyacrylamide gel. The time-resolved fluorometric detection methods using new fluorescent labels improved the detection sensitivity compared to those of previously-described methods. This paper reviews those developments of applications of lanthanide fluorescent labels for various purposes: time-resolved fluorometric high performance liquid chromatography, time-resolved fluorescent immunoassay, and protein staining in recent years.
引用
收藏
页码:397 / 410
页数:14
相关论文
共 171 条
[81]  
MacBeath G, 2000, SCIENCE, V289, P1760
[82]  
MANDLE RM, 1983, Patent No. 4372745
[83]   Highly sensitive time-resolved fluorometric determination of estrogens by high-performance liquid chromatography using a β-diketonate europium chelate [J].
Matsumoto, K ;
Tsukahara, Y ;
Uemura, T ;
Tsunoda, K ;
Kume, H ;
Kawasaki, S ;
Tadano, J ;
Matsuya, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02) :135-142
[84]   A core-shell-type fluorescent nanosphere possessing reactive poly(ethylene glycol) tethered chains on the surface for zeptomole detection of protein in time-resolved fluorometric immunoassay [J].
Matsuya, T ;
Tashiro, S ;
Hoshino, N ;
Shibata, N ;
Nagasaki, Y ;
Kataoka, K .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6124-6132
[85]   Synthesis, purification, and stability of β-diketonate europium chelate reagent, determined by RP-HPLC [J].
Matsuya, T ;
Hoshino, N ;
Harita, T ;
Ogasawara, M ;
Arao, S .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (18) :2807-2820
[86]  
MATSUYA T, 2004, THESIS METROPOLITAN
[87]  
MATSUYA T, 2002, CHROMATOGRAPHY, V23, P73
[88]  
MATSUYA T, 1999, B OGATA I MED CHEM R, P13
[89]  
MATSUYA T, 2002, ENV SCI, V9, P393
[90]   A new time-resolved fluorometric microarray detection system using core-shell-type fluorescent nanosphere and its application to allergen microarray [J].
Matsuya, Takeshi ;
Otake, Kazuhiko ;
Tashiro, Shigeru ;
Hoshino, Nobuhiro ;
Katada, Motomi ;
Okuyama, Tsuneo .