Design of lanthanide complex probes for highly sensitive time-resolved fluorometric detection methods and its application to biochemical, environmental and clinical analyses

被引:16
作者
Matsuya, Takeshi
Hoshino, Nobuhiro
Okuyama, Tsuneo
机构
[1] Mitsubishi Kagaku Iatron Inc, Dept Res & Dev, Yachiyo, Chiba 2760046, Japan
[2] Prot Technos Inst, Kanagawa 2430206, Japan
关键词
lanthanide complex; fluorescent label; time-resolved fluorescence; high-performance liquid chromatography; immunoassay; electrophoresis;
D O I
10.2174/157341106778520526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lanthanide complexes have been used for fluorescent labels to the wide variety of analytical methods including high performance liquid chromatography, immunoassay, and fluorescent imaging with time-resolved fluorometric measurements. Introduction of a time-resolved fluorometric measurement has been permitted the easy distinction of a specific long-lived fluorescence signal from short-lived natural background fluorescence present in most biological samples, reaction wells and optical components. Recently, new fluorescent labels and new instruments have been reported for time-resolved fluorescence including high performance liquid chromatography as in environmental analysis as river water, clinical chemistry as allergen assay, and a biochemical analysis as in staining method of proteins on polyacrylamide gel. The time-resolved fluorometric detection methods using new fluorescent labels improved the detection sensitivity compared to those of previously-described methods. This paper reviews those developments of applications of lanthanide fluorescent labels for various purposes: time-resolved fluorometric high performance liquid chromatography, time-resolved fluorescent immunoassay, and protein staining in recent years.
引用
收藏
页码:397 / 410
页数:14
相关论文
共 171 条
[61]  
Karp M T, 1983, J Appl Biochem, V5, P399
[62]   Analysis of steroids in environmental water samples using solid-phase extraction and ion-trap gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry [J].
Kelly, C .
JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) :309-314
[63]   A novel method using edge detection for signal extraction from cDNA microarray image analysis [J].
Kim, JH ;
Kim, HY ;
Lee, YS .
EXPERIMENTAL AND MOLECULAR MEDICINE, 2001, 33 (02) :83-88
[64]   Quantitative measurement of serum allergen-specific IgE on protein chip [J].
Kim, TE ;
Park, SW ;
Cho, NY ;
Choi, SY ;
Yong, TS ;
Nahm, BH ;
Lee, S ;
Noh, G .
EXPERIMENTAL AND MOLECULAR MEDICINE, 2002, 34 (02) :152-158
[65]   ENERGY MIGRATION IN LANTHANIDE CHELATES [J].
KLEINERMAN, M .
JOURNAL OF CHEMICAL PHYSICS, 1969, 51 (06) :2370-+
[66]  
KOLLER E, 1989, APPL FLUORESC TECHNO, V1, P1
[67]  
KOOY D, 1979, SCIENCE, V204, P873
[68]   Indirect time-resolved fluorescence detection of both non-fluorescent and fluorescent compounds separated by high-performance liquid chromatography [J].
Kurosu, Y ;
Iwata, T ;
Tsuji, A ;
Maeda, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 787 (1-2) :261-265
[69]  
Laganà A, 2000, RAPID COMMUN MASS SP, V14, P401, DOI 10.1002/(SICI)1097-0231(20000331)14:6<401::AID-RCM883>3.0.CO
[70]  
2-7