A simplified model of the source channel of the Leksell Gamma Knife®:: testing multisource configurations with PENELOPE

被引:20
作者
Al-Dweri, FMO [1 ]
Lallena, AM [1 ]
机构
[1] Univ Granada, Dept Fis Moderna, E-18071 Granada, Spain
关键词
D O I
10.1088/0031-9155/49/15/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A simplification of the source channel geometry of the Leksell Gamma Knife(R) (GK), recently proposed by the authors and checked for a single source configuration (Al-Dweri F M O, Lallena A M and Vilches M 2004 Phys. Med. Biol. 49 2687-703), has been used to calculate the dose distributions along the x, y and z axes in a water phantom with a diameter of 160 mm, for different configurations of the Gamma Knife, including 201, 150 and 102 unplugged sources. The code PENELOPE (v. 2001) has been used to perform the Monte Carlo simulations. In addition, the output factors for the 14, 8 and 4 mm helmets have been calculated. The results found for the dose profiles show a qualitatively good agreement with previous ones obtained with EGS4 and PENELOPE (v. 2000) codes and with the predictions of GammaPlan(R). The output factors obtained with our model agree within the statistical uncertainties with those calculated with the same Monte Carlo codes and with those measured with different techniques. Owing to the accuracy of the results obtained and to the reduction in the computational time with respect to full geometry simulations (larger than a factor 15), this simplified model opens the possibility of using Monte Carlo tools for planning purposes in the Gamma Knife(R).
引用
收藏
页码:3441 / 3453
页数:13
相关论文
共 14 条
[1]   A simplified model of the source channel of the Leksell GammaKnife® tested with PENELOPE [J].
Al-Dweri, FM ;
Lallena, AM ;
Vilches, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2687-2703
[2]   Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system [J].
Cheung, JYC ;
Yu, KN ;
Yu, CP ;
Ho, RTK .
MEDICAL PHYSICS, 1998, 25 (09) :1673-1675
[3]   Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit [J].
Cheung, JYC ;
Yu, KN ;
Ho, RTK ;
Yu, CP .
MEDICAL PHYSICS, 1999, 26 (07) :1252-1256
[4]   Monte Carlo calculated output factors of a Leksell Gamma Knife unit [J].
Cheung, JYC ;
Yu, KN ;
Ho, RTK ;
Yu, CP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :N247-N249
[5]   Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations [J].
Cheung, JYC ;
Yu, KN ;
Yu, CP ;
Ho, RTK .
APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) :461-465
[6]   Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55 [J].
Cheung, YC ;
Yu, KN ;
Ho, RTK ;
Yu, CP .
APPLIED RADIATION AND ISOTOPES, 2000, 53 (03) :427-430
[7]  
*EL INSTR AB, 1992, LEKS GAMM UN US MAN
[8]   Simulation of dose distribution irradiation by the Leksell Gamma Unit [J].
Liu, XW ;
Zhang, CX .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02) :441-445
[9]   An efficient method of measuring the 4 mm helmet output factor for the Gamma Knife [J].
Ma, LJ ;
Li, XA ;
Yu, CX .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :729-733
[10]   Monte Carlo simulation of the Leksell Gamma Knife®:: I.: Source modelling and calculations in homogeneous media [J].
Moskvin, V ;
DesRosiers, C ;
Papiez, L ;
Timmerman, R ;
Randall, M ;
DesRosiers, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (12) :1995-2011