Validation and qualification: the fitness for purpose of mass spectrometry-based analytical methods and analytical systems

被引:24
作者
Careri, Maria [1 ]
Mangia, Alessandro [1 ]
机构
[1] Univ Parma, Dipartimento Chim Gen & Inorgan, Consorzio Interuniv Ric Metodol Analit & Controll, CIMACO, I-43100 Parma, Italy
关键词
analytical methods; analytical systems; mass spectrometry; validation; qualification;
D O I
10.1007/s00216-006-0581-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The context of validation for mass spectrometry (MS)-based methods is critically analysed. The focus is on the fitness for purpose depending on the task of the method. Information is given on commonly accepted procedures for the implementation and acceptance of analytical methods as 'confirmatory methods' according to EU criteria, and strategies for measurement. Attention is paid to the problem of matrix effects in the case of liquid chromatography-mass spectrometry-based procedures, since according to recent guidelines for bioanalytical method validations, there is a need to evaluate matrix effects during development and validation of LC-MS methods "to ensure that precision, selectivity and sensitivity will not be compromised". Beneficial aspects of the qualification process to ensure the suitability of the MS analytical system are also evaluated and discussed.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 52 条
[1]   The ECHO technique -: the more effective way of data evaluation in liquid chromatography-tandem mass spectrometry analysis [J].
Alder, L ;
Lüderitz, S ;
Lindtner, K ;
Stan, HJ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :67-79
[2]  
*AM SOC MASS SPECT, 1997, GUID WRIT SOP MASS S
[3]   Trends in the identification of organic residues and contaminants:: EC regulations under revision [J].
André, F ;
De Wasch, KKG ;
De Brabander, HF ;
Impens, SR ;
Stolker, LAM ;
van Ginkel, L ;
Stephany, RW ;
Schilt, R ;
Courtheyn, D ;
Bonnaire, Y ;
Fürst, P ;
Gowik, P ;
Kennedy, G ;
Kuhn, T ;
Moretain, JP ;
Sauer, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (08) :435-445
[4]  
[Anonymous], 1994, 5725 ISO
[5]   Validation of analytical methods based on mass spectrometric detection according to the "2002/657/EC" European decision: guideline and application [J].
Antignac, JP ;
Le Bizec, B ;
Monteau, F ;
Andre, F .
ANALYTICA CHIMICA ACTA, 2003, 483 (1-2) :325-334
[6]  
*AOAC INT, 1995, QUICK EAS
[7]   Quantitative characterization of differential ion suppression on liquid chromatography/atmospheric pressure ionization mass spectrometric bioanalytical methods [J].
Avery, MJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (03) :197-201
[8]  
Baldwin R, 1997, J AM SOC MASS SPECTR, V8, P1180
[9]   Determination of heterocyclic amines by liquid chromatography-quadrupole time-of-flight mass spectrometry [J].
Barceló-Barrachina, E ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) :409-418
[10]   Countering matrix effects in environmental liquid chromatography-electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals [J].
Benijts, T ;
Dams, R ;
Lambert, W ;
De Leenheer, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :153-159