An electroenzymatic L-glutamate microbiosensor selective against dopamine

被引:59
作者
Hamdi, Naser
Wang, Jianjun
Walker, Eric
Maidment, Nigel T.
Monbouquette, Harold G. [1 ]
机构
[1] Univ Calif Los Angeles, Biomed Engn Interdept Grad Program, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Chem Engn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Neurosci Interdept Program, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Semel Inst Neurosci & Human Behav, Dept Psychiat & Biobehav Sci, Los Angeles, CA 90095 USA
关键词
glutamate microbiosensor; platinized electrode; overoxidized polypyrrole; platinum black;
D O I
10.1016/j.jelechem.2006.03.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In designing an amperometric (L)-glutamate biosensor based on the electrochemical detection of enzymatically generated H2O2, the key challenges are selectivity against electrooxidizable interferents, micromolar detection limit, and response time of seconds or less. With these issues in mind, a glutamate microbiosensor consisting of Pt black (PtB1k) electrodeposited on a 125-mu m-dia. Pt wire with a permselective film of electropolymerized, overoxidized polypyrrole (OPP) and a top layer of (L)-glutamate oxidase ((L)-GluOx) crosslinked with glutaraldehyde was constructed. The OPP film permits passage of H2O2 to the electrode surface while rejecting the common interferents of brain extracellular fluid, ascorbate (AA) and dopamine (DA). The PtB1k treatment of Pt electrodes was adopted since the microscale roughness of PtB1k increases the effective surface area of the electrode and promotes electrochemical H202 oxidation at lower potential. This microbiosensor was highly sensitive (80 +/- 10 nA mu M-1 cm(-2)) to (L)-glutamate at 450 mV versus Ag/AgCl, a significantly lower potential than the similar to 700 mV used with most similar (L)-glutamate sensors prepared on polished Pt electrodes. Notably, microbiosensor response to both AA and DA was undetectable at concentrations exceeding physiological extracellular concentrations of these compounds. The described (L)-glutamate biosensor also showed excellent response time (similar to 1-2 s) and temporal stability (similar to 3 week half-life). In addition, this microbiosensor was robust enough for insertion into live brain tissue where it responded rapidly to (L)-glutamate, but was insensitive to dopamine. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 55 条
[1]   A MEDIATED AMPEROMETRIC ENZYME ELECTRODE USING TETRATHIAFULVALENE AND L-GLUTAMATE OXIDASE FOR THE DETERMINATION OF L-GLUTAMIC ACID [J].
ALMEIDA, NF ;
MULCHANDANI, AK .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :353-361
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .4. COIMMOBILIZATION OF GLUCOSE-OXIDASE AND FERRO FERRICYANIDE IN POLY(NORMAL-METHYLPYRROLE) FILMS [J].
BARTLETT, PN ;
ALI, Z ;
EASTWICKFIELD, V .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (18) :2677-2683
[3]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[4]   ELECTROCONDUCTING CONJUGATED POLYMERS - NEW SENSITIVE MATRICES TO BUILD UP CHEMICAL OR ELECTROCHEMICAL SENSORS - A REVIEW [J].
BIDAN, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :45-56
[5]   ENZYME PACKED-BED SYSTEM FOR THE ONLINE MEASUREMENT OF GLUCOSE, GLUTAMATE, AND LACTATE IN BRAIN MICRODIALYSATE [J].
BOUTELLE, MG ;
FELLOWS, LK ;
COOK, C .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1790-1794
[6]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[7]   INTERACTIONS BETWEEN GLUTAMATERGIC AND MONOAMINERGIC SYSTEMS WITHIN THE BASAL GANGLIA - IMPLICATIONS FOR SCHIZOPHRENIA AND PARKINSONS-DISEASE [J].
CARLSSON, M ;
CARLSSON, A .
TRENDS IN NEUROSCIENCES, 1990, 13 (07) :272-276
[8]  
CONN PJ, 1997, PHARMACOL TOXICOL, V37, P205, DOI DOI 10.1146/ANNUREV.PHARMT0X.37.1.2059131252
[9]   GLUTAMATE OXIDASE ENZYME ELECTRODES - MICROSENSORS FOR NEUROTRANSMITTER DETERMINATION USING ELECTROCHEMICALLY POLYMERIZED PERMSELECTIVE FILMS [J].
COOPER, JM ;
FOREMAN, PL ;
GLIDLE, A ;
LING, TW ;
PRITCHARD, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 388 (1-2) :143-149
[10]  
COOPER JM, 1994, J MATER SCI-MATER EL, V5, P111