Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report

被引:470
作者
Stroom, JC [1 ]
Heijmen, BJM [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, Div Clin Phys, NL-3075 EA Rotterdam, Netherlands
关键词
radiotherapy; geometrical uncertainties; planning target volume; margins; International Commission on Radiation Units and Measurements;
D O I
10.1016/S0167-8140(02)00140-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
In this paper, we elaborate on the proposals in the ICRU-62 report concerning planning target volume (PTV) margins for geometrical uncertainties during radiotherapy, such as variations in patient set-up and internal organ motion. According to the ICRU, these margins should be such that the planned dose in the PTV is representative of the real dose in the 'moving' clinical target volume (CTV). We demonstrate that the dosimetrical consequences of systematic and random geometrical uncertainties are fundamentally different, which should be reflected in margin calculations. The recommendation in the ICRU-62 report, to quadratically add standard deviations for systematic (Sigma(tot)) and random (sigma(tot)) errors to determine an overall standard deviation for margin calculations, is therefore generally not valid. Instead, a previously published recipe for PTV margin calculation, M=2Sigma(tot) + 0.7sigma(tot), does indeed account for the different impact of systematic and random errors on the dose in the CTV. If, for both random and systematic uncertainties, the internal and external errors are uncorrelated and quantified by the standard deviations sigma(int), sigma(ext), Sigma(int), Sigma(ext), then Sigma(tot) = root(Sigma(int)(2) + Sigma(ext)(2)) and sigma(tot) = root(sigma(int)(2) + sigma(ext)(2)). If the PTV margin thus acquired is deliberately reduced to spare normal tissues, the planned PTV dose is not representative of the CTV anymore. Therefore, we recommend to also report the minimum dose in the volume originally defined by the recipe (designated RTV, i.e. representative target volume). (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 22 条
[1]
Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[2]
High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[3]
MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[4]
A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[5]
Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning [J].
de Boer, HCJ ;
De Koste, JRV ;
Senan, S ;
Visser, AG ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :857-868
[6]
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[7]
International Commission on Radiation Units and Measurement, 1999, 62 ICRU S
[8]
A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy [J].
Killoran, JH ;
Kooy, HM ;
Gladstone, DJ ;
Welte, FJ ;
Beard, CJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :213-221
[9]
IMPLEMENTATION OF RANDOM POSITIONING ERROR IN COMPUTERIZED RADIATION TREATMENT PLANNING SYSTEMS AS A RESULT OF FRACTIONATION [J].
LEONG, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03) :327-334
[10]
A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans [J].
Mageras, GS ;
Kutcher, GJ ;
Leibel, SA ;
Zelefsky, MJ ;
Melian, E ;
Mohan, R ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :333-342