Improvement of surface acoustic wave gas and biosensor response characteristics using a capacitive coupling technique

被引:30
作者
Bender, F [1 ]
Länge, K [1 ]
Voigt, A [1 ]
Rapp, M [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Instrumental Anal, D-76021 Karlsruhe, Germany
关键词
D O I
10.1021/ac035019+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As for many other electronic devices and circuits, electrical contact to surface acoustic wave sensors is usually made using bonding wires. Ibis technique is known to result in reliable contact under most conditions, but it does so with several disadvantages. First, electrical contact is not reversible, impeding replacement of sensor devices. Second, bonding wires are quite delicate and should not be exposed to high gas or liquid flows. Third, the presence of bonding wires may limit the potential to miniaturize a sensor housing or flow cell. Therefore, a capacitive coupling technique was developed to replace bonding wires. This permitted redesign of flow cells and sensor arrays, resulting in flow cell volumes of 80 muL to 60 nL. As a consequence, response times were reduced to 1-2 s in gas sensing and a few minutes in liquid sensing, respectively. At the same time, sensor devices can be easily replaced, and the system is less susceptible to malfunction.
引用
收藏
页码:3837 / 3840
页数:4
相关论文
共 14 条
[1]  
Avramov I. D., 2000, IEEE EIA INT FREQ CO
[2]   Investigations on plasma-polymer-coated SAW and STW resonators for chemical gas-sensing applications [J].
Avramov, ID ;
Kurosawa, S ;
Rapp, M ;
Krawczak, P ;
Radeva, EI .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2001, 49 (04) :827-837
[3]   Covalent photolinker-mediated immobilization of an intermediate dextran layer to polymer-coated surfaces for biosensing applications [J].
Barie, N ;
Rapp, M ;
Sigrist, H ;
Ache, HJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :855-860
[4]  
BARIE N, 2003, UNPUB SENS ACTUATO B
[5]   Contactless surface acoustic wave gas sensor [J].
Beck, K ;
Kunzelmann, T ;
von Schickfus, M ;
Hunklinger, S .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 76 (1-3) :103-106
[6]   Development of a preconcentration unit for a SAW sensor micro array and its use for indoor air quality monitoring [J].
Bender, F ;
Barié, N ;
Romoudis, G ;
Voigt, A ;
Rapp, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :135-141
[7]   Quality tests of electronic noses:: the influence of sample dilution and sensor drifts on the pattern recognition for selected case studies [J].
Frank, M ;
Hermle, T ;
Ulmer, H ;
Mitrovics, J ;
Weimar, U ;
Göpel, W .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) :88-90
[8]   A contactless surface acoustic wave biosensor [J].
Freudenberg, J ;
Schelle, S ;
Beck, K ;
von Schickfus, M ;
Hunklinger, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (04) :423-425
[9]   A NEW GENERAL SYNTHETIC METHOD FOR PREPARATION OF LINEAR POLY-P-XYLYLENES [J].
GORHAM, WF .
JOURNAL OF POLYMER SCIENCE PART A-1-POLYMER CHEMISTRY, 1966, 4 (12PA) :3027-&
[10]   A surface acoustic wave biosensor concept with low flow cell volumes for label-free detection [J].
Länge, K ;
Bender, F ;
Voigt, A ;
Gao, H ;
Rapp, M .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5561-5566