Execution of a single-isocenter three-field technique, using a multileaf collimator or tray-mounted cerrobend blocks: Effect on treatment time

被引:12
作者
DeMeerleer, GO
Derie, CMT
Vakaet, L
Fortan, LG
Mersseman, BKG
DeNeve, WJ
机构
[1] Division of Radiotherapy, University Hospital, Gent
[2] University Hospital Gent, Division of Radiotherapy (P7), B-9000 Gent
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 39卷 / 01期
关键词
multileaf collimator; breast cancer; one point setup irradiation;
D O I
10.1016/S0360-3016(97)00306-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this article, we studied the total treatment time of a single-isocenter three-field irradiation of breast and axilla, using either tray-mounted cerrobend blocks, or a multileaf collimator (MLC) for field shaping, Methods and Materials: A total of 20 female, unselected patients were given 50 Gy (2 Gy/fraction) on breast and 46 Gy on axilla and supraclavicular region (2 Gy/fraction). Patients were randomized between two different treatment groups, The first group (it = 10) was treated on a Philips SL-75 linear accelerator (SL-75), using 5 MV photons with tray-mounted cerrobend blocks, The second group (ii = 10) was treated on a Philips SL-25 linear accelerator, using 6 MV photons and a MLC (SL-25-MLC). Results: Although the beam-on time on the SL-25-MLC was significantly higher (p < 0.0001) compared to the SL-75, overall treatment time was significantly shorter using a MLC instead of tray-mounted cerrobend blocks (p < 0.0001), The difference in total treatment time was in the range of 100 s per patient per day, The main difference between the two accelerators was observed when setup of the second and third field was done using the automatic setup facility of the SL-25-MLC (avoids entering the treatment room), A mean time gain of 124 s per treatment session was observed using automatic setup, Considering the yearly number of patients receiving this treatment, a total time gain equivalent to 16.15 8-h workdays was calculated, Conclusions: Compared to a technique using tray-mounted cerrobend blocks in the single-isocenter three-field irradiation of a breast and axilla, a MLC combined with automatic field setup provides a significant time advantage, by reducing the number of manipulations inside the treatment room, (C) 1997 Elsevier Science Inc.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 17 条
[1]   Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray [J].
Adams, EJ ;
Hounsell, AR .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (03) :225-229
[2]   A NONDIVERGENT 3 FIELD MATCHING TECHNIQUE FOR BREAST IRRADIATION [J].
CHU, JCH ;
SOLIN, LJ ;
HWANG, CC ;
FOWBLE, B ;
HANKS, GE ;
GOODMAN, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1037-1040
[3]  
FERGUSON GA, 1981, STAT ANAL PSYCHOL ED, P142
[4]   THE ACCEPTABILITY OF A MULTILEAF COLLIMATOR AS A REPLACEMENT FOR CONVENTIONAL BLOCKS [J].
FERNANDEZ, EM ;
SHENTALL, GS ;
MAYLES, WPM ;
DEARNALEY, DP .
RADIOTHERAPY AND ONCOLOGY, 1995, 36 (01) :65-74
[5]   Effects of treatment setup variation on beam's eye view dosimetry for radiation therapy using the multileaf collimator vs the cerrobend block [J].
Frazier, A ;
Yan, D ;
Du, M ;
Wong, J ;
Vicini, F ;
Matter, R ;
Joyce, M ;
Martinez, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1247-1256
[6]   RADIATION-THERAPY OF STAGE-I BREAST-CANCER - ANALYSIS OF TREATMENT TECHNIQUE ACCURACY USING 3-DIMENSIONAL TREATMENT PLANNING TOOLS [J].
GAGLIARDI, G ;
LAX, I ;
RUTQVIST, LE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (02) :94-101
[7]   Field edge smoothing for multileaf collimators [J].
Galvin, JM ;
Leavitt, DD ;
Smith, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (01) :89-94
[8]   TECHNIQUE FOR BREAST IRRADIATION USING CUSTOM BLOCKS CONFORMING TO THE CHEST-WALL CONTOUR [J].
HARTSELL, WF ;
MURTHY, AK ;
KIEL, KD ;
KAO, M ;
HENDRICKSON, FR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :189-195
[9]   HIGH-TECHNOLOGY TO SIMPLIFY THE PLANNING AND DELIVERY OF RADIOTHERAPY [J].
HOUNSELL, AR ;
MARRS, JE ;
MOORE, CJ ;
SHARROCK, PJ ;
SHAW, AJ ;
WILKINSON, JM ;
WILLIAMS, PC .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :192-196
[10]   MATCHLINE DOSIMETRY OF A 3 FIELD TECHNIQUE FOR BREAST TREATMENT USING COBALT OR 6 MV X-RAYS [J].
HUNT, MA ;
KUTCHER, GJ ;
MARTEL, MK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (07) :1099-1106