Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery

被引:32
作者
Vatnitsky, SM
Schulte, RWM
Galindo, R
Meinass, HJ
Miller, DW
机构
[1] Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, CA 92354
关键词
D O I
10.1088/0031-9155/42/10/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work we studied the feasibility of radiochromic him for dosimetry verification of proton Bragg peak stereotactic radiosurgery with multiple beams. High-sensitivity MD-55 radiochromic film was calibrated for proton beam irradiation and the RIT 113 system was employed for him evaluation. Simulated stereotactic radiosurgery with a special phantom arrangement for film dosimetry was performed, following the same procedure as for a patient undergoing treatment. Five-beam irradiation was developed using a 3D treatment planning system. This plan was then delivered to the phantom in a one-day experiment. Planned and measured composite dose distributions were compared. Spatial accuracy of dose delivery to a region containing a simulated critical structure was evaluated for a single portal. Radiochromic film dosimetry validated the prescribed dose delivery within +/-5%, one standard deviation, by comparing calculated doses with measured values. The alignment of apertures and boluses, as well as the alignment of the phantom with respect to the isocentre, was confirmed. Spatial accuracy of the method would have been able to detect possible misalignments greater than +/-2 mm. We have demonstrated how radiochromic film dosimetry can be used to measure complex dose distributions in an irradiated phantom, thus enabling us to verify planned dose delivery of proton Bragg peak stereotactic radiosurgery with multiple beams. We assume that the dosimetric agreement between planned and measured dose distributions for the reported simulations will apply to patient treatments.
引用
收藏
页码:1887 / 1898
页数:12
相关论文
共 23 条
[1]  
*AAPM, 1995, N54 AAPM
[2]   THE EFFECT OF PATIENT MOTION ON DOSE UNCERTAINTY IN CHARGED-PARTICLE IRRADIATION FOR LESIONS ENCIRCLING THE BRAIN-STEM OR SPINAL-CORD [J].
DAFTARI, I ;
PETTI, PL ;
COLLIER, JM ;
CASTRO, JR ;
PITLUCK, S .
MEDICAL PHYSICS, 1991, 18 (06) :1105-1115
[3]   Use of a micro-ionization chamber and an anthropomorphic head phantom in a quality assurance program for stereotactic radiosurgery [J].
Duggan, DM ;
Coffey, CW .
MEDICAL PHYSICS, 1996, 23 (04) :513-516
[4]  
Fabrikant J I, 1992, Neurosurg Clin N Am, V3, P99
[5]   MULTIDIMENSIONAL TREATMENT PLANNING .2. BEAM EYE-VIEW, BACK PROJECTION, AND PROJECTION THROUGH CT SECTIONS [J].
GOITEIN, M ;
ABRAMS, M ;
ROWELL, D ;
POLLARI, H ;
WILES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06) :789-797
[6]   CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY [J].
GOITEIN, M .
MEDICAL PHYSICS, 1985, 12 (05) :608-612
[7]  
Hartmann G, 1995, QUALITY ASSURANCE PR
[8]  
KJELLBERG RN, 1986, ANN CLIN RES, V18, P17
[9]  
KONNOV B, 1989, P INT WORKSH PROT NA, P56
[10]   DETERMINING LOCATIONS OF INTRACEREBRAL LESIONS FOR PROTON RADIOTHERAPY [J].
LEVIN, CV ;
HOUGH, J ;
ADAMS, LP ;
BOONZAIER, D ;
RUTHER, H ;
WYNCHANK, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (10) :1393-1401