High-throughput sample handling and data collection at synchrotrons: embedding the ESRF into the high-throughput gene-to-structure pipeline

被引:60
作者
Beteva, A.
Cipriani, F.
Cusack, S.
Delageniere, S.
Gabadinho, J.
Gordon, E. J.
Guijarro, M.
Hall, D. R.
Larsen, S.
Launer, L.
Lavault, C. B.
Leonard, G. A.
Mairs, T.
McCarthy, A.
McCarthy, J.
Meyer, J.
Mitchell, E.
Monaco, S.
Nurizzo, D.
Pernot, P.
Pieritz, R.
Ravelli, R. G. B.
Rey, V.
Shepard, W.
Spruce, D.
Stuart, D. I.
Svensson, O.
Theveneau, P.
Thibault, X.
Turkenburg, J.
Walsh, M.
McSweeney, S. M.
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] European Mol Biol Lab, F-38042 Grenoble, France
[3] MRC, F-38042 Grenoble 9, France
[4] Oxford Prot Prod Facil, Oxford OX3 7BN, England
[5] Well Trust Ctr Human Genet, Div Struct Biol, Oxford OX3 7BN, England
[6] Univ York, Dept Chem, York Struct Biol Lab, York YO10 5DD, N Yorkshire, England
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2006年 / 62卷
基金
英国医学研究理事会;
关键词
D O I
10.1107/S0907444906032859
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automatic data- collection system has been implemented and installed on seven insertion- device beamlines and a bending- magnet beamline at the ESRF ( European Synchrotron Radiation Facility) as part of the SPINE ( Structural Proteomics In Europe) development of an automated structure- determination pipeline. The system allows remote interaction with beamline- control systems and automatic sample mounting, alignment, characterization, data collection and processing. Reports of all actions taken are available for inspection via database modules and web services.
引用
收藏
页码:1162 / 1169
页数:8
相关论文
共 33 条
[1]   Recent developments in the PHENIX software for automated crystallographic structure determination [J].
Adams, PD ;
Gopal, K ;
Grosse-Kunstleve, RW ;
Hung, LW ;
Ioerger, TR ;
McCoy, AJ ;
Moriarty, NW ;
Pai, RK ;
Read, RJ ;
Romo, TD ;
Sacchettin, JC ;
Sauter, NK ;
Storoni, LC ;
Terwilligerf, TC .
JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 :53-55
[2]   PHENIX:: building new software for automated crystallographic structure determination [J].
Adams, PD ;
Grosse-Kunstleve, RW ;
Hung, LW ;
Ioerger, TR ;
McCoy, AJ ;
Moriarty, NW ;
Read, RJ ;
Sacchettini, JC ;
Sauter, NK ;
Terwilliger, TC .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2002, 58 :1948-1954
[3]   Using image analysis for automated crystal positioning in a synchrotron X-ray beam for high-throughput macromolecular crystallography [J].
Andrey, P ;
Lavault, B ;
Cipriani, F ;
Maurin, Y .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2004, 37 :265-269
[4]   Automation of macromolecular crystallography beamlines [J].
Arzt, S ;
Beteva, A ;
Cipriani, F ;
Delageniere, S ;
Felisaz, F ;
Förstner, G ;
Gordon, E ;
Launer, L ;
Lavault, B ;
Leonard, G ;
Mairs, T ;
McCarthy, A ;
McCarthy, J ;
McSweeney, S ;
Meyer, J ;
Mitchell, E ;
Monaco, S ;
Nurizzo, D ;
Ravelli, R ;
Rey, V ;
Shepard, W ;
Spruce, D ;
Svensson, O ;
Theveneau, P .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2005, 89 (02) :124-152
[5]   SPINE workshop on automated X-ray analysis: a progress report [J].
Bahar, M. ;
Ballard, C. ;
Cohen, S. X. ;
Cowtan, K. D. ;
Dodson, E. J. ;
Emsley, P. ;
Esnouf, R. M. ;
Keegan, R. ;
Lamzin, V. ;
Langer, G. ;
Levdikov, V. ;
Long, F. ;
Meier, C. ;
Muller, A. ;
Murshudov, G. N. ;
Perrakis, A. ;
Siebold, C. ;
Stein, N. ;
Turkenburg, M. G. W. ;
Vagin, A. A. ;
Winn, M. ;
Winter, G. ;
Wilson, K. S. .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :1170-1183
[6]  
Booch G, 2002, OBJECT ORIENTED ANAL
[7]   A quantitative approach to data-collection strategies [J].
Bourenkov, GP ;
Popov, AN .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :58-64
[8]   Automation of sample mounting for macromolecular crystallography [J].
Cipriani, F. ;
Felisaz, F. ;
Launer, L. ;
Aksoy, J. -S. ;
Caserotto, H. ;
Cusack, S. ;
Dallery, M. ;
di-Chiaro, F. ;
Guijarro, M. ;
Huet, J. ;
Larsen, S. ;
Lentini, Mario ;
McCarthy, J. ;
McSweeney, S. ;
Ravelli, R. ;
Renier, M. ;
Taffut, C. ;
Thompson, A. ;
Leonard, G. A. ;
Walsh, M. A. .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :1251-1259
[9]   An automated system to mount cryo-cooled protein crystals on a synchrotron beamline, using compact sample cassettes and a small-scale robot [J].
Cohen, AE ;
Ellis, PJ ;
Miller, MD ;
Deacon, AM ;
Phizackerley, RP .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2002, 35 :720-726
[10]   Scaling and assessment of data quality [J].
Evans, P .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :72-82