Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization

被引:118
作者
Kratzsch, C [1 ]
Tenberken, O [1 ]
Peters, FT [1 ]
Weber, AA [1 ]
Kraemer, T [1 ]
Maurer, HH [1 ]
机构
[1] Univ Saarland, Inst Expt & Clin Pharmacol & Toxicol, Dept Expt & Clin Toxicol, D-64421 Homburg, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 08期
关键词
liquid chromatography/mass spectrometry; benzodiazepines; flumazenil; hypnotics; plasma;
D O I
10.1002/jms.599
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic/mass spectrometric assay with atmospheric pressure chemical ionization (LC/APCI-MS) is presented for fast and reliable screening and identification and also for precise and sensitive quantification in plasma of the 23 benzodiazepines alprazolam, bromazepam, brotizolam, camazepam, chlordiazepoxide, clobazam, clonazepam, diazepam, flunitrazepam, flurazepam, desalkylflurazepam, lorazepam, lormetazepam, medazepam, metaclazepam, midazolam, nitrazepam, nordazepam, oxazepam, prazepam, temazepam and tetrazepam, triazolam, their antagonist flumazenil and the benzodiazepine BZ(1) (omega 1) receptor agonists zaleplone, zolpidem and zopiclone. It allows confirmation of the diagnosis of an overdose situation and monitoring of psychiatric patients' compliance. The analytes were isolated from plasma using liquid-liquid extraction and were separated on a Merck LiChroCART column with Superspher 60 RP Select B as the stationary phase. Gradient elution was performed using aqueous ammonium formate and acetonitrile. After screening and identification in the scan mode using the authors' LC/MS library, the analytes were quantified in the selected-ion monitoring mode. The quantification assay was fully validated. It was found to be selective and proved to be linear from sub-therapeutic to over therapeutic concentrations for all analytes, except bromazepam. The corresponding reference levels and the assay's accuracy and precision data for all studied substances are listed. The accuracy and precision data were within the required limits with the exception of those for bromazepam. The analytes were stable in frozen plasma for at least 1 month. The validated assay was successfully applied to several authentic plasma samples from patients treated or intoxicated with various benzodiazepines or with zaleplone, zolpidem or zopiclone. It has proven to be appropriate for the isolation, separation, screening, identification and quantification of the drugs mentioned above in plasma for clinical toxicology, e.g. in cases of poisoning, and forensic toxicology, e.g. in cases of driving under the influence of drugs. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:856 / 872
页数:17
相关论文
共 44 条
[11]   SIMULTANEOUS SCREENING AND QUANTITATION OF ALPIDEM, ZOLPIDEM, BUSPIRONE AND BENZODIAZEPINES BY DUAL-CHANNEL GAS-CHROMATOGRAPHY USING ELECTRON-CAPTURE AND NITROGEN-PHOSPHORUS DETECTION AFTER SOLID-PHASE EXTRACTION [J].
GAILLARD, Y ;
GAYMONTCHAMP, JP ;
OLLAGNIER, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (02) :197-208
[12]   Micro-extraction of chlordiazepoxide and its primary metabolites, desmethylchlordiazepoxide and demoxepam, from plasma and their measurement by liquid chromatography [J].
Garretty, DJ ;
Wolff, K ;
Hay, AWM .
ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 :528-533
[13]   Determination of zaleplon and zolpidem by liquid chromatography-turbo-ionspray mass spectrometry: application to forensic cases [J].
Giroud, C ;
Augsburger, M ;
Menetrey, A ;
Mangin, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (01) :131-138
[14]   SIMPLIFIED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CLONAZEPAM AND OTHER BENZODIAZEPINES IN SERUM [J].
HAVER, VM ;
PORTER, WH ;
DORIE, LD ;
LEA, JR .
THERAPEUTIC DRUG MONITORING, 1986, 8 (03) :352-357
[15]   DETERMINATION OF NITRAZEPAM AND TEMAZEPAM IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HO, PC ;
TRIGGS, EJ ;
HEAZLEWOOD, V ;
BOURNE, DWA .
THERAPEUTIC DRUG MONITORING, 1983, 5 (03) :303-307
[16]   Determination of sedatives and anesthetics in plasma by liquid chromatography mass spectrometry with a desalting system [J].
Kanazawa, H ;
Konishi, Y ;
Matsushima, Y ;
Takahashi, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :227-236
[17]   Determination of 1,4-benzodiazepines by high-performance liquid chromatography electrospray tandem mass spectrometry [J].
Kleinschnitz, M ;
Herderich, M ;
Schreier, P .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 676 (01) :61-67
[18]   Screening, library-assisted identification and validated quantification of fifteen neuroleptics and three of their metabolites in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization [J].
Kratzsch, C ;
Peters, FT ;
Kraemer, T ;
Weber, AA ;
Maurer, HH .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (03) :283-295
[19]  
KRATZSCH C, 2003, IN PRES P 13 GTFCH S
[20]  
KRATZSCH C, 2001, P 13 GTFCH S MOSB, V76