Quantification of Trace Elements in Natural Samples by Electrospray Ionization Mass Spectrometry with a Size-Exclusion Column Based on the Formation of Metal-Aminopolycarboxylate Complexes

被引:17
作者
Hotta, Hiroki [1 ]
Mori, Takayuki [1 ]
Takahashi, Akira [1 ]
Kogure, Yuta [1 ]
Johno, Keita [1 ]
Umemura, Tomonari [2 ]
Tsunoda, Kin-ichi [1 ]
机构
[1] Gunma Univ, Dept Chem & Biol Chem, Tenjin, Kiryu 3768515, Japan
[2] Nagoya Univ, Grad Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
PRESSURE CHEMICAL-IONIZATION; LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; ESI-MS; SIGNAL SUPPRESSION; BIOANALYTICAL METHODS; SPECIATION ANALYSIS; ANALYTE RESPONSE; EDTA COMPLEXES; HUMAN PLASMA;
D O I
10.1021/ac9006842
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Metal ions were determined by ESI-MS in the negative ion mode as monovalent negative ions of their aminopolycarboxylic acid (APC) complexes, e.g., [Al(cydta)](-), [Pb(Hcydta)](-), where excess amounts of the APC agents were added to sample solutions. Among several APCs studied, we chose trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid (CyDTA) as the best chelating agent because of higher stabilities and higher sensitivities of the complexes. The ionization efficiency of these metal complexes was strongly affected by the presence of matrix salts, e.g., NaCl, KNO3, and etc. Thus, a size exclusion column (Sephadex G-10) was used for the online separation of the metal-APC complexes from other matrix salts. Ibis method was successfully applied to the quantitative analyses for total amounts of Al, Ni, Cu, Zn, and Ph in the biological certified reference materials, olive leaves (BCR-062) and plankton (BCR-414). The detection limits of the present methods for these elements were several to several ten nanomolar levels. Moreover, this approach was extended to determine ultratraces of fluoride based on the formation of the ternary complex of aluminum, fluoride and nitrilotriacetic acid (NTA), i.e., [AlF(nta)](-). Its detection limit was 10 nM and was 2 orders of magnitude better than that of a fluoride ion selective electrode method. This method was applied to determine fluoride in tap water, river water, and green tea samples.
引用
收藏
页码:6357 / 6363
页数:7
相关论文
共 62 条
[1]
ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - QUANTITATIVE ASPECTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :649-654
[2]
Determination of synthetic ferric chelates used as fertilizers by liquid chromatography-electrospray/mass spectrometry in agricultural matrices [J].
Alvarez-Fernandez, Ana ;
Orera, Irene ;
Abadia, Javier ;
Abadia, Anunciacion .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (01) :37-47
[3]
Determination of common inorganic anions and cations by non-suppressed ion chromatography with column switching [J].
Amin, Muhammad ;
Lim, Lee Wah ;
Takeuchi, Toyohide .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1182 (02) :169-175
[4]
Quantitative characterization of differential ion suppression on liquid chromatography/atmospheric pressure ionization mass spectrometric bioanalytical methods [J].
Avery, MJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (03) :197-201
[5]
High sensitivity analysis of neutral underivatized oligosaccharides by nanoelectrospray mass spectrometry [J].
Bahr, U ;
Pfenninger, A ;
Karas, M ;
Stahl, B .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4530-4535
[6]
Quantitative electrospray mass spectrometry of halides and halogenic anions [J].
Barnett, DA ;
Horlick, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :497-501
[7]
Analysis of metal-EDTA complexes by electrospray mass spectrometry [J].
Baron, D ;
Hering, JG .
JOURNAL OF ENVIRONMENTAL QUALITY, 1998, 27 (04) :844-850
[8]
Indirect determination of trace amounts of fluoride in natural waters by ion chromatography:: a comparison of on-line post-column fluorimetry and ICP-MS detectors [J].
Bayón, MM ;
Garcia, AR ;
Alonso, JIG ;
Sanz-Medel, A .
ANALYST, 1999, 124 (01) :27-31
[9]
Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[10]
Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387