Evaluation of a new method for automated detection of left ventricular boundaries in time series of magnetic resonance images using an active appearance motion model

被引:46
作者
van der Geest, RJ
Lelieveldt, BPF
Angelié, E
Danilouchkine, M
Swingen, C
Sonka, M
Reiber, JHC
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc,LKEB, NL-2333 ZA Leiden, Netherlands
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
[3] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
magnetic resonance imaging; global ventricular function; automated analysis;
D O I
10.1081/JCMR-120038082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was the evaluation of a computer algorithm for the automated detection of endocardial and epicardial boundaries of the left ventricle in time series of short-axis magnetic resonance images based on an Active Appearance Motion Model (AAMM). In 20 short-axis MR examinations, manual contours were defined in multiple temporal frames (from end-diastole to end-systole) in multiple slices from base to apex. Using a leave-one-out procedure, the image data and contours were used to build 20 different AAMMs giving a statistical description of the ventricular shape, gray value appearance, and cardiac motion patterns in the training set. Automated contour detection was performed by iteratively deforming the AAMM within statistically allowed limits until an optimal match was found between the deformed AAMM and the underlying image data of the left-out subject. Global ventricular function results derived from automatically detected contours were compared with results obtained from manually traced boundaries. The AAMM contour detection method was successful in 17 of 20 studies. The three failures were excluded from further statistical analysis. Automated contour detection resulted in small, but statistically nonsignificant, underestimations of ventricular volumes and mass: differences for end-diastolic volume were 0.3% +/- 12.0%, for end-systolic volume 2.0% +/- 23.4% and for left ventricular myocardial mass 0.73% +/- 14.9% (mean +/- SD). An excellent agreement was observed in the ejection fraction: difference of 0.1% +/- 6.7%. In conclusion, the presented fully automated contour detection method provides assessment of quantitative global function that is comparable to manual analysis.
引用
收藏
页码:609 / 617
页数:9
相关论文
共 12 条
[1]   AUTOMATED MYOCARDIAL EDGE-DETECTION FROM BREATH-HOLD CINE-MR IMAGES - EVALUATION OF LEFT-VENTRICULAR VOLUMES AND MASS [J].
BALDY, C ;
DOUEK, P ;
CROISILLE, P ;
MAGNIN, IE ;
REVEL, D ;
AMIEL, M .
MAGNETIC RESONANCE IMAGING, 1994, 12 (04) :589-598
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[5]  
Cootes TF, 1999, LECT NOTES COMPUT SC, V1613, P322
[6]   Heart disease: Functional evaluation with MR imaging [J].
Higgins, CB ;
Sakuma, H .
RADIOLOGY, 1996, 199 (02) :307-315
[7]   Automatic detection of left ventricular contours from cardiac cine magnetic resonance imaging using fuzzy logic [J].
Lalande, A ;
Legrand, L ;
Walker, PM ;
Guy, F ;
Cottin, Y ;
Roy, S ;
Brunotte, F .
INVESTIGATIVE RADIOLOGY, 1999, 34 (03) :211-217
[8]   Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion [J].
Lee, VS ;
Resnick, D ;
Bundy, JM ;
Simonetti, OP ;
Lee, P ;
Weinreb, JC .
RADIOLOGY, 2002, 222 (03) :835-842
[9]   Multistage hybrid active appearance model matching: Segmentation of left and right ventricles in cardiac MR images [J].
Mitchell, SC ;
Lelieveldt, BPF ;
van der Geest, RJ ;
Bosch, HG ;
Reiber, JHC ;
Sonka, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (05) :415-423
[10]   Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging [J].
Plein, S ;
Bloomer, TN ;
Ridgway, JP ;
Jones, TR ;
Bainbridge, GJ ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :230-236