State-of-the-art of the hyphenation of capillary electrochromatography with mass spectrometry

被引:50
作者
Barceló-Barrachina, E [1 ]
Moyano, E [1 ]
Galceran, MT [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
capillary electrochromatography; mass spectrometry; review;
D O I
10.1002/elps.200305908
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high separation efficiency and loading capacity of capillary electrochromatography (CEC) make it an attractive separation mode for coupling with mass spectrometry (MS), which has the ability to unambiguously identify analytes with high selectivity and sensitivity. We present an overview of recent advances on both instrumentation and separation columns employed in CEC-MS systems. In particular, the main characteristics of the stationary phases, as well as the configurations of the column outlet that are related with the coupling arrangements of the MS ionization sources, are reported. At present, packed columns and conventional electrospray ionization (ESI) sources are mainly employed in CEC-MS. Nevertheless, the use of monolithic capillary columns and nanoelectrospray sources has the potential for wide acceptance in the next future. Moreover, the main features of several mass analyzers including ion trap, quadrupole, time-of-flight, magnetic sector, and Fourier transform-ion cyclotron resonance are examined. Finally, current applications of this technology, mainly in the pharmaceutical field and proteomics, are reviewed.
引用
收藏
页码:1927 / 1948
页数:22
相关论文
共 86 条
[21]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[22]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[23]   LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY [J].
FORET, F ;
THOMPSON, TJ ;
VOUROS, P ;
KARGER, BL ;
GEBAUER, P ;
BOCEK, P .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4450-4458
[24]   Ion trap mass spectrometry as detector for capillary electrochromatography of peptides: Possibilities and limitations [J].
Gaspari, M ;
Gucek, M ;
Walhagen, K ;
Vreeken, RJ ;
Verheij, ER ;
Tjaden, UR ;
van der Greef, J .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (06) :243-249
[25]   DEVELOPMENT OF PACKED CAPILLARY COLUMN ELECTROCHROMATOGRAPHY MASS-SPECTROMETRY [J].
GORDON, DB ;
LORD, GA ;
JONES, DS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :544-548
[26]  
Gucek M, 2000, RAPID COMMUN MASS SP, V14, P1448
[27]   Polymeric monolithic stationary phases for capillary electrochromatography [J].
Hilder, EF ;
Svec, F ;
Fréchet, JMJ .
ELECTROPHORESIS, 2002, 23 (22-23) :3934-3953
[28]   Use of a mixed-mode packing and voltage tuning for peptide mixture separation in pressurized capillary electrochromatography with an ion trap storage reflectron time of flight mass spectrometer detector [J].
Huang, PQ ;
Jin, XY ;
Chen, YJ ;
Srinivasan, JR ;
Lubman, DM .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1786-1791
[29]   Separation of tryptic digests using a modified buffer in pressurized capillary electrochromatography with an ion trap storage reflectron time-of-flight mass spectrometer [J].
Huang, PQ ;
Wu, JT ;
Lubman, DM .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3003-3008
[30]   PSEUDO-ELECTROCHROMATOGRAPHY NEGATIVE-ION ELECTROSPRAY MASS-SPECTROMETRY OF AROMATIC GLUCURONIDES AND FOOD COLORS [J].
HUGENER, M ;
TINKE, AP ;
NIESSEN, WMA ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 647 (02) :375-385