Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-μm porous particles

被引:150
作者
Fountain, Kenneth J. [1 ]
Neue, Uwe D. [1 ]
Grumbach, Eric S. [1 ]
Diehl, Diane M. [1 ]
机构
[1] Waters Corp, Chem Appl Technol, Milford, MA 01757 USA
关键词
Band spreading; UPLC; Kinetic plots; Sub-2-mu m particles; KINETIC PLOT METHOD; MU-M; CONVENTIONAL COLUMNS; DISPERSION; EFFICIENCY; EQUATIONS; PHASE; HPLC; LC; INSTRUMENTATION;
D O I
10.1016/j.chroma.2009.06.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effects of extra-column band spreading, LC system operating pressure, and separation temperature were investigated for sub-2-mu m particle columns using both a conventional HPLC system as well as a UPLC (R) system. The contributions of both volume- and time-based extra-column effects were analyzed in detail. In addition, the performance difference between columns containing 2.5 and 1.7-mu m particles (same stationary phase) was studied. The performance of these columns was compared using a conventional HPLC system and a low dead volume UPLC system capable of routine operation up to 1000 bar. The system contribution to band spreading and the pressure limitations of the conventional HPLC system were found to be the main difficulties that prevented acceptable performance of the sub-2-mu m particle columns. Finally, an increase in operating temperature needs to be accompanied by an increase in flow rate to prevent a loss of separation performance. Thus, at a fixed column length, an increase in temperature is not a substitute for the need for very high operating pressures. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5979 / 5988
页数:10
相关论文
共 41 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]  
ANSPACH JA, 2006, 30 INT S EXH HIGH PE
[3]   ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[4]   DISPERSION OF PEAKS BY SHORT STRAIGHT OPEN TUBES IN LIQUID-CHROMATOGRAPHY SYSTEMS [J].
ATWOOD, JG ;
GOLAY, MJE .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :97-122
[5]   Approximate transient and long time limit solutions for the band broadening induced by the thin sidewall-layer in liquid chromatography columns [J].
Broeckhoven, Ken ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) :25-39
[6]  
Butchart K., 2007, INT LABMATE, P6
[7]   Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems I: Intrinsic performance comparison [J].
Cabooter, D. ;
Heinisch, S. ;
Rocca, J. L. ;
Clicq, D. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :121-133
[8]   Kinetic plot and particle size distribution analysis to discuss the performance limits of sub-2 μm and supra-2 μm particle columns [J].
Cabooter, Deirdre ;
Billen, Jeroen ;
Terryn, Herman ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) :1-10
[9]   Method to predict and compare the influence of the particle size on the isocratic peak capacity of high-performance liquid chromatography columns [J].
Cabooter, Deirdre ;
de Villiers, Andre ;
Clicq, David ;
Szucs, Roman ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1147 (02) :183-191
[10]   Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible time [J].
Cabooter, Deirdre ;
Lestremau, Francois ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) :23-34