Carotid artery stents on CT angiography: In vitro comparison of different stent designs and sizes using 16-, 64-and 320-row CT scanners

被引:7
作者
Lettau, Michael [1 ,2 ]
Kotter, Elmar [3 ]
Bendszus, Martin [2 ]
Haehnel, Stefan [2 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Neurosurg, Div Neuroradiol, D-79106 Freiburg, Germany
[2] Heidelberg Univ, Med Ctr, Dept Neurol, Div Neuroradiol, D-69120 Heidelberg, Germany
[3] Univ Freiburg, Med Ctr, Dept Radiol, D-79106 Freiburg, Germany
关键词
Carotid artery stents; In vitro; CTA; Different CT scanners; ALN; DUAL-ENERGY CT; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; MULTIDETECTOR CT; MR-ANGIOGRAPHY; RESTENOSIS; ENDARTERECTOMY; ANGIOPLASTY; STENOSIS; FRACTURE; KERNELS;
D O I
10.1016/j.neurad.2013.10.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Background and purpose: CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. Material and methods: CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. Results: ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. Conclusion: CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 35 条
[1]
Optimal carotid duplex velocity criteria for defining the severity of carotid in-stent restenosis [J].
AbuRahma, Ali F. ;
Abu-Halimah, Shadi ;
Bensenhaver, Jessica ;
Dean, L. Scott ;
Keiffer, Tammi ;
Emmett, Mary ;
Flaherty, Sarah .
JOURNAL OF VASCULAR SURGERY, 2008, 48 (03) :589-594
[2]
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[3]
Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective study [J].
Bendszus, M ;
Koltzenburg, M ;
Burger, R ;
Warmuth-Metz, M ;
Hofmann, E ;
Solymosi, L .
LANCET, 1999, 354 (9190) :1594-1597
[4]
Bladin CF, 1996, INT ANGIOL, V15, P295
[5]
Carotid Stent Fracture: Diagnosis and Management [J].
Boehm, Gernot ;
Gschwendtner, Manfred ;
Schillinger, Martin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (02) :273-277
[6]
Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography [J].
Carbone, Iacopo ;
Francone, Marco ;
Algeri, Emanuela ;
Granatelli, Antonino ;
Napoli, Alessandro ;
Kirchin, Miles A. ;
Catalano, Carlo ;
Passariello, Roberto .
EUROPEAN RADIOLOGY, 2008, 18 (02) :234-243
[7]
Carotid artery stenting performed with a flow-reversal technique: Improved technical performance [J].
de Castro-Afonso, Luis Henrique ;
de Oliveira, Livia ;
Pontes-Neto, Octavio Marques ;
Cabette Fabio, Soraia Ramos ;
Wajnberg, Eduardo ;
Abud, Daniel Giansante .
JOURNAL OF NEURORADIOLOGY, 2013, 40 (01) :29-37
[8]
Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Boogers, Mark J. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Reiber, Johannes H. C. ;
Sieders, Allard ;
Spano, Fabrizio ;
Jukema, J. Wouter ;
Schalij, Martin J. ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :331-340
[9]
Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial (vol 7, pg 893, 2008) [J].
Eckstein, H-H ;
Ringleb, P. ;
Allenberg, J-R .
LANCET NEUROLOGY, 2009, 8 (02) :135-135
[10]
The value of dual-energy CTA for control of surgically clipped aneurysms [J].
Fahrendorf, Delia M. ;
Goericke, Sophia L. ;
Oezkan, Neriman ;
Breyer, Tobias ;
Hussain, Sajid ;
Sandalcioglu, Erol I. ;
Sure, Ulrich ;
Forsting, Michael ;
Gizewski, Elke R. .
EUROPEAN RADIOLOGY, 2011, 21 (10) :2193-2201