Clinical application of the PFA-100®

被引:152
作者
Favaloro, EJ [1 ]
机构
[1] Westmead Hosp, ICPMR, Dept Hematol, Diagnost Haemostasis Lab,Western Sydney Area Hlth, Westmead, NSW 2145, Australia
关键词
D O I
10.1097/00062752-200209000-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The PFA-100((R)) (platelet function analyzer) is a relatively new tool for the investigation of primary hemostasis. Recent studies have shown its utility as a screening tool for investigating possible von Willebrand disorder (VWD) and various platelet disorders. More recently, the PFA-100((R)) has been shown to be valuable in monitoring desmopressin acetate (DDAVP) therapy in both VWD and platelet disorders. The PFA-100((R)) has also been evaluated in many other studies for its utility in assessing drug effects, for potential monitoring of antiplatelet medication (including aspirin), or for evaluation of overall primary hemostasis in various clinical disorders or during surgical procedures. This article reviews current findings and highlights the benefits and limitations of the clinical utility of the PFA-100((R)). Ultimately, the greatest strengths of the PFA-100((R)) are its simplicity of use and excellent sensitivity to particular hemostatic disturbances such as VWD, platelet disorders, and platelet-affecting medication. However, because it is thus a global test system, this also creates a significant limitation because the PFA-100((R)) is not specific for, nor predictive of, any particular disorder. However, used appropriately, the PFA-100((R)) can be considered a worthwhile addition to any hemostasis laboratory involved in the diagnosis or therapeutic monitoring of bleeding disorders and potentially of antiplatelet medication. This review should be valuable to both hemostasis scientists and clinical specialists. Curr Opin Hematol 2002, 9:407-415 (C) 2002 Lippincott Williams Wilkins, Inc.
引用
收藏
页码:407 / 415
页数:9
相关论文
共 98 条
[41]   Platelet hyperreactivity after coronary artery bypass grafting: the possible relevance to glycoprotein polymorphisms. A preliminary report [J].
Golanski, J ;
Golanski, R ;
Chizynski, K ;
Iwaszkiewicz, A ;
Rozalski, M ;
Wieclawska, B ;
Boncler, M ;
Watala, C .
PLATELETS, 2001, 12 (04) :241-247
[42]   Profile and prevalence of aspirin resistance in patients with cardiovascular disease [J].
Gum, PA ;
Kottke-Marchant, K ;
Poggio, EC ;
Gurm, H ;
Welsh, PA ;
Brooks, L ;
Sapp, SK ;
Topol, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03) :230-235
[43]  
Harrison P, 2000, BRIT J HAEMATOL, V111, P733
[44]   Performance of the platelet function analyser PFA-100® in testing abnormalities of primary haemostasis [J].
Harrison, P ;
Robinson, MSC ;
Mackie, IJ ;
Joseph, J ;
McDonald, SJ ;
Liesner, R ;
Savidge, GF ;
Pasi, J ;
Machin, SJ .
BLOOD COAGULATION & FIBRINOLYSIS, 1999, 10 (01) :25-31
[45]   Comparison of four commercial citrate blood collection systems for platelet function analysis by the PFA-100(TM) system [J].
Heilmann, EJ ;
Kundu, SK ;
Sio, R ;
Garcia, C ;
Gomez, R ;
Christie, DJ .
THROMBOSIS RESEARCH, 1997, 87 (01) :159-164
[46]   Use ct the PFA-100™ apparatus to assess platelet function in patients undergoing PTCA during and after infusion of cE3 Fab in the presence of other antiplatelet agents [J].
Hézard, N ;
Metz, D ;
Nazeyrollas, P ;
Droulle, C ;
Elaerts, J ;
Potron, G ;
Nguyen, P .
THROMBOSIS AND HAEMOSTASIS, 2000, 83 (04) :540-544
[47]   Monitoring of aspirin (ASA) pharmacodynamics with the platelet function analyzer PFA-100® [J].
Homoncik, M ;
Jilma, B ;
Hergovich, N ;
Stohlawetz, P ;
Panzer, S ;
Speiser, W .
THROMBOSIS AND HAEMOSTASIS, 2000, 83 (02) :316-321
[48]   Systemic inflammation increases shear stress-induced platelet plug formation measured by the PFA-100 [J].
Homoncik, M ;
Blann, AD ;
Hollenstein, U ;
Pernerstorfer, T ;
Eichler, HG ;
Jilma, B .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 111 (04) :1250-1252
[49]   RETRACTED: Influence of different colloids on molecular markers of haemostasis and platelet function in patients undergoing major abdominal surgery (Retracted Article) [J].
Hüttner, T ;
Boldt, J ;
Haisch, G ;
Suttner, S ;
Kumle, B ;
Schulz, H .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (03) :417-423
[50]   Evaluation of primary hemostasis in neonates with a new in vitro platelet function analyzer [J].
Israels, SJ ;
Cheang, T ;
McMillan-Ward, EM ;
Cheang, M .
JOURNAL OF PEDIATRICS, 2001, 138 (01) :116-119