Three-year results of proximal tibia fractures treated with the LISS

被引:45
作者
Boldin, Christian [1 ]
Fankhauser, Florian [1 ]
Hofer, Herwig Peter [1 ]
Szyszkowitz, Rudolf [1 ]
机构
[1] Med Univ, Dept Trauma Surg, Graz, Austria
关键词
D O I
10.1097/01.blo.0000203467.58431.a0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Proximal tibia fractures present a difficult treatment challenge with historically high complication rates. In a prospective study, we asked whether the Less Invasive Stabilization System (LISS) plate can adequately treat extraarticular and complex intraarticular proximal tibia fractures and provide low complication rates and acceptable long-term functional outcomes. We prospectively observed 25 patients with 26 proximal tibia fractures (AO type A2, A3, C1, C2, or C3) treated with the LISS. Consecutive 3-year followup included radiographs and clinical examinations using Knee Society scores and Hospital for Special Surgery scores for extraarticular and intraarticular fractures. No loss of reduction occurred in patients with extraarticular fractures, whereas varus malalignment occurred in one patient with an intraarticular fracture. Two patients with AO 41 C 3.3 fractures had severe knee arthrosis develop and had total knee replacements. The mean Knee Society scores and final average Hospital for Special Surgery scores were similar for extraarticular and intraarticular fractures. Complications related to the surgery included one delayed union and implant removal in two patients. The LISS provided stable fixation of extraarticular and intraarticular proximal tibia fractures and good functional outcomes with a low complication rate. In complex articular fractures additional screws should be used.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 43 条
[11]
Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating [J].
Egol, KA ;
Su, E ;
Tejwani, NC ;
Sims, SH ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (02) :340-346
[12]
FREEDMAN EL, 1995, CLIN ORTHOP RELAT R, P25
[13]
LISS PLT: Design, mechanical and biomechanical characteristics [J].
Goesling, T ;
Frenk, A ;
Appenzeller, A ;
Garapati, R ;
Marti, A ;
Krettek, C .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 :S11-S15
[14]
Biomechanical investigation of the primary stability of intramedullary compression nails in the proximal tibia: experimental study using interlocking screws in cryopreserved human tibias [J].
Gollwitzer, H ;
Karampour, K ;
Hauschild, M ;
Diehl, P ;
Busch, R ;
Mittelmeier, W .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (01) :22-28
[15]
PROBLEMS IN THE MANAGEMENT OF TYPE-III (SEVERE) OPEN FRACTURES - A NEW CLASSIFICATION OF TYPE-III OPEN FRACTURES [J].
GUSTILO, RB ;
MENDOZA, RM ;
WILLIAMS, DN .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1984, 24 (08) :742-746
[16]
PREVENTION OF INFECTION IN TREATMENT OF 1000 AND 25 OPEN FRACTURES OF LONG BONES - RETROSPECTIVE AND PROSPECTIVE ANALYSES [J].
GUSTILO, RB ;
ANDERSON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) :453-458
[17]
INFLUENCES OF SOME DESIGN PARAMETERS ON THE BIOMECHANICS OF THE UNREAMED TIBIAL INTRAMEDULLARY NAIL [J].
HENLEY, MB ;
MEIER, M ;
TENCER, AF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :311-319
[18]
A biomechanical analysis of internal fixation of complex tibial plateau fractures [J].
Horwitz, DS ;
Bachus, KN ;
Craig, MA ;
Peters, CL .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) :545-549
[19]
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[20]
The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails [J].
Krettek, C ;
Miclau, T ;
Schandelmaier, F ;
Stephan, C ;
Möhlmann, U ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) :550-553