Adverse Bioeffects of Ultrasound Contrast Agents Used in Echocardiography: True Safety Issue or "Much Ado About Nothing"?

被引:11
作者
Aggeli, Constadina [1 ]
Giannopoulos, Georgios [1 ]
Lampropoulos, Konstantinos [1 ]
Pitsavos, Christos [1 ]
Stefanadis, Christodoulos [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 1, Hippokration Hosp, GR-11527 Athens, Greece
关键词
Ultrasound contrast agents; contrast echocardiography; coronary artery disease; safety; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; ACUTE MYOCARDIAL-INFARCTION; PREMATURE VENTRICULAR CONTRACTIONS; CORONARY-ARTERY-DISEASE; BLOOD-BRAIN-BARRIER; MICROBUBBLE DESTRUCTION; PERFUSION DEFECTS; DIAGNOSTIC ULTRASOUND; COMPARATIVE ACCURACY; PULSED ULTRASOUND;
D O I
10.2174/157016109788340695
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Ultrasound contrast agents, consisting of gas-filled microbubbles, have long been used to enhance ultrasonographic imaging of various organs and in several settings. In echocardiography, after their first use for Doppler signal enhancement, their applications have expanded and several studies, combining a range of stress modalities with myocardial contrast echocardiography have shown the clinical utility of these agents. In experimental isolated heart animal models, the interaction of ultrasound with echo-contrast microbubbles was shown to have significant biologic effects when the acoustic energy of the beam exceeded a threshold, leading them to rupture and causing cavitation phenomena; the observed consequences in the experimental setting included microvascular damage, transient decrease of contractile performance and increased lactate production. From the clinical point of view, the reporting of a number of serious adverse events-whose association with the echo-contrast agents was debated-has led to the addition of warning boxes in the prescribing documentation of these preparations. On the other hand, clinical studies including high numbers of patients have shown good safety and tolerance of contrast use during stress echocardiography, both for left ventricle opacification and myocardial perfusion imaging. The present review aims at presenting a balanced account of the existing data regarding the mechanisms and clinical implications of echo-contrast bioeffects, in order to make an informed assessment of their safety in clinical practice.
引用
收藏
页码:338 / 346
页数:9
相关论文
共 75 条
[1]   Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for the detection of ischaemia in 5250 studies [J].
Aggeli, C. ;
Giannopoulos, G. ;
Roussakis, G. ;
Christoforatou, E. ;
Marinos, G. ;
Toli, C. ;
Pitsavos, C. ;
Stefanadis, C. .
HEART, 2008, 94 (12) :1571-1577
[2]   Real-time three-dimensional dobutamine stress echocardiography for coronary artery disease diagnosis: validation with coronary angiography [J].
Aggeli, Constadina ;
Giannopoulos, Georgios ;
Misovoulos, Platon ;
Roussakis, George ;
Christoforatou, Euaggelia ;
Kokkinakis, Christos ;
Brili, Stela ;
Stefanadis, Christodoulos .
HEART, 2007, 93 (06) :672-675
[3]  
*AIUM, 2000, J ULTRAS MED, V19, P120
[4]   Destruction of contrast microbubbles by ultrasound - Effects on myocardial function, coronary perfusion pressure, and microvascular integrity [J].
Ay, T ;
Havaux, X ;
Van Camp, G ;
Campanelli, B ;
Gisellu, G ;
Pasquet, A ;
Denef, JF ;
Melin, JA ;
Vanoverschelde, JLJ .
CIRCULATION, 2001, 104 (04) :461-466
[5]   Noninvasive in vivo clot dissolution without a thrombolytic drug - Recanalization of thrombosed iliofemoral arteries by transcutaneous ultrasound combined with intravenous infusion of microbubbles [J].
Birnbaum, Y ;
Luo, H ;
Nagai, T ;
Fishbein, MC ;
Peterson, TM ;
Li, SP ;
Kricsfeld, D ;
Porter, TR ;
Siegel, RJ .
CIRCULATION, 1998, 97 (02) :130-134
[6]  
*BM SQUIBB MED IM, 2002, DEF PERFL LIP MICR V
[7]   Myocardial contrast echocardiography versus dobutamine echocardiography for predicting functional recovery after acute myocardial infarction treated with primary coronary angioplasty [J].
Bolognese, L ;
Antoniucci, D ;
Rovai, D ;
Buonamici, P ;
Cerisano, G ;
Santoro, GM ;
Marini, C ;
LAbbate, A ;
Fazzini, PF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (07) :1677-1683
[8]   Does contrast echocardiography with Optison induce myocardial necrosis in humans? [J].
Borges, AC ;
Walde, T ;
Reibis, RK ;
Grohmann, A ;
Ziebig, R ;
Rutsch, W ;
Schimke, I ;
Baumann, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) :1080-1086
[9]  
Cancer therapy evaluation program, COMM TERM CRIT ADV E
[10]   BIOEFFECTS IN ECHOCARDIOGRAPHY [J].
CARSTENSEN, EL ;
DUCK, FA ;
MELTZER, RS ;
SCHWARZ, KQ ;
KELLER, B .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (06) :605-623