Biomechanical comparison of kyphoplasty with different bone cements

被引:113
作者
Tomita, S [1 ]
Molloy, S [1 ]
Jasper, LE [1 ]
Abe, M [1 ]
Belkoff, SM [1 ]
机构
[1] Johns Hopkins Univ, Johns Hopkins Bayview Med Ctr, Dept Orthopaed Surg, Baltimore, MD USA
关键词
kyphoplasty; alpha-tricalcium phosphate cement; polymethylmethacrylate;
D O I
10.1097/00007632-200406010-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Ex vivo biomechanical study. Objectives. To compare the biomechanical properties of isolated, fractured, osteoporotic vertebral bodies after treatment by kyphoplasty with one of two cements: alpha-tricalcium phosphate cement (Biopex-R; Mitsubishi Materials Corp., Tokyo, Japan) or polymethylmethacrylate ( Simplex P; Stryker-Howmedica-Osteonics, Mahwah, NJ). Summary of Background Data. Kyphoplasty and vertebroplasty typically use polymethylmethacrylate cements for the treatment of osteoporotic compression fractures. Scant information exists regarding the use of alternative cements in kyphoplasty. Methods. Simulated compression fractures were created in 24 vertebral bodies (T6-T9, L2-L5) harvested from three female cadavers. Vertebral bodies were assigned to one of two groups: kyphoplasty with Biopex-R or kyphoplasty with Simplex P. The kyphoplasty treatment consisted of inserting bone tamps bipedicularly into each vertebral body, inflating the tamp, and filling the created void with Biopex-R or Simplex P. Pretreatment and posttreatment heights were measured, and the repaired vertebral bodies were recompressed to determine posttreatment strength and stiffness values. Differences were checked for significance (P < 0.05) using a repeated-measures analysis of variance followed by Tukey's test. Results. Kyphoplasty with Biopex-R restored strength in the lumbar and thoracic vertebral bodies. Kyphoplasty with Simplex P displayed significantly greater posttreatment strength than initial strength in the thoracic region. Vertebral bodies augmented with either cement were significantly less stiff than their initial conditions, except for the thoracic vertebrae treated with Simplex P, in which stiffness was restored. There was no significant difference in percentage of height restored between the cement treatments. Conclusions. Kyphoplasty with either cement restored initial strength. In general, stiffness was not restored.
引用
收藏
页码:1203 / 1207
页数:5
相关论文
共 30 条
[1]
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures [J].
Bai, B ;
Jazrawi, LM ;
Kummer, FJ ;
Spivak, JM .
SPINE, 1999, 24 (15) :1521-1526
[2]
Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[3]
The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[4]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[5]
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture [J].
Belkoff, SM ;
Mathis, JM ;
Fenton, DC ;
Scribner, RM ;
Reiley, ME ;
Talmadge, K .
SPINE, 2001, 26 (02) :151-156
[6]
Belkoff SM, 2001, AM J NEURORADIOL, V22, P1212
[7]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[8]
Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[9]
Belkoff SM, 2002, AM J NEURORADIOL, V23, P1647
[10]
Bostrom MP, 1997, SPINE S, V22, P38, DOI DOI 10.1097/00007632-199712151-00007