Low-Cost HIV-1 Diagnosis and Quantification in Dried Blood Spots by Real Time PCR

被引:34
作者
Mehta, Nishaki
Trzmielina, Sonia
Nonyane, Bareng A. S.
Eliot, Melissa N.
Lin, Rongheng
Foulkes, Andrea S.
McNeal, Kristina
Ammann, Arthur
Eulalievyolo, Vindu
Sullivan, John L.
Luzuriaga, Katherine
Somasundaran, Mohan
Somasundaran, Mohan
机构
[1] Department of Pediatrics, Program in Molecular Medicine, University of Massachusetts Medical School, Worcester, MA
[2] School of Public Health and Health Sciences, University of Massachusetts at Amherst, Amherst, MA
[3] Global Strategies for HIV Prevention, San Rafael, CA
[4] Heal Africa Hospital, Goma
[5] Texas Tech University Health Sciences Center, Paul L Foster School of Medicine, El Paso, TX
[6] London School of Hygiene and Tropical Medicine, London
来源
PLOS ONE | 2009年 / 4卷 / 06期
关键词
D O I
10.1371/journal.pone.0005819
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. Methods and Findings: We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log(10), and %CV <8% up to 4 log(10) dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r=0.91) and branched DNA (r=0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. Conclusions: The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings.
引用
收藏
页数:10
相关论文
共 65 条
[41]   Whole blood versus plasma spots for measurement of HIV-1 viral load in HIV-infected African patients [J].
Mwaba, P ;
Cassol, S ;
Nunn, A ;
Pilon, R ;
Chintu, C ;
Janes, M ;
Zumla, A .
LANCET, 2003, 362 (9401) :2067-2068
[42]  
NGOGIANGHUONG N, 2008, J ACQUIR IMMUNE DEFI
[43]   Diagnosis of HIV infection in children [J].
Nielsen, K ;
Bryson, YJ .
PEDIATRIC CLINICS OF NORTH AMERICA, 2000, 47 (01) :39-+
[44]  
*NIH, 1996, TECHN UT HIV BLOOD E, P17
[45]   Use of dried whole blood spots for quantification of HIV-1 RNA [J].
O'Shea, S ;
Mullen, J ;
Corbett, K ;
Chrystie, I ;
Newell, ML ;
Banatvala, JE .
AIDS, 1999, 13 (05) :630-631
[46]  
Panther KU, 1999, POLISH STUD, V1, P37
[47]   SYBR green-based real-time quantitative PCR assay for detection of West Nile virus circumvents false-negative results due to strain variability [J].
Papin, JF ;
Vahrson, W ;
Dittmer, DP .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) :1511-1518
[48]  
*PATHF INT KEN PRE, 2007, EARL DIAGN HIV DRIED
[49]   Evaluation of the ultrasensitive human immunodeficiency virus type 1 (HIV-1) p24 antigen assay performed on dried blood spots for diagnosis of HIV-1 infection in infants [J].
Patton, Janet C. ;
Coovadia, Ashraf H. ;
Meyers, Tammy M. ;
Sherman, Gayle G. .
CLINICAL AND VACCINE IMMUNOLOGY, 2008, 15 (02) :388-391
[50]   Evaluation of dried whole blood spots obtained by heel or finger stick as an alternative to venous blood for diagnosis of human immunodeficiency virus type 1 infection in vertically exposed infants in the routine diagnostic laboratory [J].
Patton, Janet C. ;
Akkers, Eveline ;
Coovadia, Ashraf H. ;
Meyers, Tammy M. ;
Stevens, Wendy S. ;
Sherman, Gayle G. .
CLINICAL AND VACCINE IMMUNOLOGY, 2007, 14 (02) :201-203