Comparison of two versions of the Vigileo-FloTrac™ system (1.03 and 1.07) for stroke volume estimation: a multicentre, blinded comparison with oesophageal Doppler measurements

被引:31
作者
Chatti, R. [6 ]
de Rudniki, S. [2 ]
Marque, S. [4 ]
Dumenil, A. S. [3 ]
Descorps-Declere, A. [3 ]
Cariou, A. [4 ]
Duranteau, J. [2 ]
Aout, M. [5 ]
Vicaut, E. [5 ]
Cholley, B. P. [1 ]
机构
[1] Univ Paris 05, Hop Europeen Georges Pompidou, AP HP, Fac Med,Serv Anesthesie Reanimat, F-75908 Paris 15, France
[2] Univ Paris 11, Hop Bicetre, AP HP, Dept Anesthesie Reanimat, Paris, France
[3] Univ Paris 11, Hop Antoine Beclere, AP HP, Dept Anesthesie Reanimat, Paris, France
[4] Univ Paris 05, Hop Cochin, AP HP, Serv Reanimat Med, Paris, France
[5] Univ Paris 07, Hop Fernand Widal, AP HP, Unite Rech Clin, Paris, France
[6] Hop Lariboisiere, AP HP, Dept Anesthesie Reanimat, F-75475 Paris, France
关键词
equipment; flowmeters; measurement techniques; flow velocity waveform; monitoring; cardiopulmonary; WAVE-FORM ANALYSIS; OUTPUT MONITORING-SYSTEM; CARDIAC-OUTPUT; THERMODILUTION TECHNIQUE; SURGERY; AGREEMENT; VALIDITY;
D O I
10.1093/bja/aep020
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Our aim was to evaluate the validity of stroke volume measurements obtained using the Vigileo-FloTrac (TM) system in comparison with those obtained using oesophageal Doppler considered as a reference. Prospective, multicentre study (four university hospitals), in which investigators were blinded to stroke volume values acquired simultaneously with the other technique. Two different versions of the Vigileo software (1.03 and 1.07) were studied and compared over two consecutive periods of time. Forty critically ill patients (three ICUs) and 20 high-risk surgical patients (one operating theatre) were studied over a 6-month period. Two hundred and forty paired stroke volume values obtained using the second version of the Vigileo (1.07) yielded better correlation and agreement (R=0.48, P < 0.001; bias=4 ml, limits of agreement: +/- 41 ml) than the 207 paired values obtained using version 1.03 (R=0.12, P=0.1; bias=1 ml, limits of agreement: +/- 75 ml). However, even with the second version, the percentage error in stroke volume measurement was 58%, a value still above the range considered clinically acceptable (30%). The precision of stroke volume estimation using Vigileo-FloTrac (TM) has improved with the second version of the software (1.07), but remains insufficient to allow the replacement of the reference technique in the population studied.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 28 条
  • [11] Validation of a new arterial pulse contour-based cardiac output device
    de Waal, Eric E. C.
    Kalkman, Cor J.
    Rex, Steffen
    Buhre, Wolfgang F.
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (08) : 1904 - 1909
  • [12] Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device
    Jaeggi, P
    Hofer, CK
    Klaghofer, R
    Fodor, P
    Genoni, M
    Zollinger, A
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 217 - 220
  • [13] Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
    Lefrant, JY
    Bruelle, P
    Aya, AGM
    Saissi, G
    Dauzat, M
    de La Coussaye, JE
    Eledjam, JJ
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (04) : 347 - 352
  • [14] Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform
    Lorsomradee, Suraphong
    Lorsomradee, Sratwadee
    Cromheecke, Stefanie
    De Hert, Stefan G.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (05) : 636 - 643
  • [15] Edwards FloTrac™ sensor and Vigileo™ monitor:: easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    Manecke, Gerard R.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (05) : 523 - 527
  • [16] Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration
    Manecke, Gerard R., Jr.
    Auger, William R.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (01) : 3 - 7
  • [17] Cardiac output measurement in patients undergoing liver transplantation:: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    Matthieu, Biais
    Karine, Nouette-Gaulain
    Vincent, Cottenceau
    Alain, Vallet
    Francois, Cochard Jean
    Philippe, Revel
    Francois, Sztark
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (05) : 1480 - 1486
  • [18] RETRACTED: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery (Retracted Article)
    Mayer, J.
    Boldt, J.
    Schoellhorn, T.
    Roehm, K. D.
    Mengistu, A. M.
    Suttner, S.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (02) : 176 - 182
  • [19] RETRACTED: Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device (Retracted Article)
    Mayer, Jochen
    Boldt, Joachim
    Wolf, Michael W.
    Lang, Johannes
    Suttner, Stefan
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (03) : 867 - 872
  • [20] Cardiac output monitoring: Comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery
    Mehta, Yatin
    Chand, Rajesh Kumar
    Sawhney, Ravindra
    Bhise, Milind
    Singh, Ajmer
    Trehan, Naresh
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 394 - 399