Hydrogel-actuated capacitive transducer for wireless biosensors

被引:44
作者
Strong, ZA [1 ]
Wang, AW
McConaghy, CF
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Univ Calif Davis, Dept Appl Sci, Davis, CA USA
关键词
wireless biosensor; biosensing techniques; biomedical monitoring; capacitive pressure sensor; hydrogel; NiTi diaphragm;
D O I
10.1023/A:1014627029818
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article introduces a new type of transducer that combines capacitive pressure sensing techniques with biosensitive hydrogels, using an adaptable MEMS fabrication platform. Hydrogel swelling in response to analyte concentration exerts contact pressure on a deformable conducting diaphragm, producing a capacitance change. Initial results are reported for testing device feasibility. Uncrosslinked PHEMA hydrogel was tested for swelling pressure in response to calcium nitrate tetrahydrate. Diaphragm deflection due to applied air pressure was measured on NiTi-based diaphragms and compared with hydrogel-actuated deflections of the same diaphragms to determine the pressure generating characteristics of the hydrogel. The PHEMA sample exhibited greatest sensitivity in the concentration range 0-0.5 M, generating an average of 110mN/M/mul. The device was incorporated into a passive LC resonant circuit. Resonance frequency was measured as a function of applied air pressure, in the range of pressures generated by hydrogel swelling. Resonance frequency shifted from 66 MHz to 33 MHz over the pressure range 0-32 kPa, corresponding to an estimated average sensitivity of 66 Hz per mumol of calcium nitrate tetrahydrate over the range 0-0.5 M.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 24 条
[1]  
Arquint P, 1992, J Biomater Appl, V7, P47, DOI 10.1177/088532829200700103
[2]   Functional hydrogel structures for autonomous flow control inside microfluidic channels [J].
Beebe, DJ ;
Moore, JS ;
Bauer, JM ;
Yu, Q ;
Liu, RH ;
Devadoss, C ;
Jo, BH .
NATURE, 2000, 404 (6778) :588-+
[3]   EQUILIBRIUM SWELLING BEHAVIOR OF PH-SENSITIVE HYDROGELS [J].
BRANNONPEPPAS, L ;
PEPPAS, NA .
CHEMICAL ENGINEERING SCIENCE, 1991, 46 (03) :715-722
[4]   A miniature pressure system with a capacitive sensor and a passive telemetry link for use in implantable applications [J].
Chatzandroulis, S ;
Tsoukalas, D ;
Neukomm, PA .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :18-23
[5]   pH-sensitive thin hydrogel microfabricated by photolithography [J].
Chen, GP ;
Imanishi, Y ;
Ito, Y .
LANGMUIR, 1998, 14 (22) :6610-6612
[7]  
GOMBOTZ WR, 1986, HYDROGELS MED PHARM, V1, P95
[8]  
GREGONIS DE, 1976, HYDROGELS MED RELATE, P89
[9]   Thin-Film Magnetoelastic Microsensors for Remote Query Biomedical Monitoring [J].
Grimes, Craig A. ;
Kouzoudis, Dimitris ;
Ong, Keat G. ;
Crump, Rick .
BIOMEDICAL MICRODEVICES, 1999, 2 (01) :51-60
[10]   One-chip integrated resonance circuit with a capacitive pressure sensor [J].
Husak, M .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) :173-178