New metallic MR stents for artifact-free coronary MR angiography:: Feasibility study in a swine model

被引:19
作者
Buecker, A
Spuentrup, E
Ruebben, A
Mahnken, A
Nguyen, TH
Kinzel, S
Günther, RW
机构
[1] Univ Technol, Clin Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Technol, Dept Lab Anim Sci, D-52057 Aachen, Germany
关键词
MR stents; cMRA; swine model;
D O I
10.1097/01.rli.0000116894.48384.c2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The objective of this study was to investigate the potential for artifact-free coronary magnetic resonance angiography (cMRA) in the presence of dedicated metallic MR stents in vitro and in a swine model. Methods: All investigations were performed at 1.5 T, applying a standard cMRA gradient echo sequence with a T2 preparation pulse. Two prototypes of each hand-woven, mechanically woven, and lasered Aachen Resonance Coronary MR Stents made out of an MR-compatible metallic alloy and dilated to 2.5 mm and 4 mm were examined in a water bath. Results: Artifact behavior was judged independently by 2 radiologists as showing "no artifacts" for all tested stent types. Signal-to-noise ratios inside and outside of the stents were measured yielding a Pearson correlation coefficient of 0.98 (y - 1.22 + 0.92x). Nineteen stents (8 hand woven, 3 mechanically woven, 8 lasered) were deployed in coronary arteries of 19 domestic pigs and were examined by cMRA. Artifact behavior of the stents was analyzed by measuring the signal-to-noise ratio at the stent positions and compared with signal-to-noise ratio measurements outside of the stents, yielding a Pearson correlation coefficient of 0.90 (y = -0.75 + 1.06x). Conclusions: All 3 prototypes of coronary MR stents allowed complete visualization of the stent lumen and consequently determination of stent patency by cMRA.
引用
收藏
页码:250 / 253
页数:4
相关论文
共 13 条
[1]   MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents [J].
Bartels, LW ;
Smits, HFM ;
Bakker, CJG ;
Viergever, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (03) :365-371
[2]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[3]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[4]   Coronary arterial stents: Safety and artifacts during MR imaging [J].
Hug, J ;
Nagel, E ;
Bornstedt, A ;
Schnackenburg, B ;
Oswald, H ;
Fleck, E .
RADIOLOGY, 2000, 216 (03) :781-787
[5]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869
[6]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO
[7]  
2-J
[8]   Sequential magnetic resonance monitoring of pulmonary flow with endovascular stents placed across the pulmonary valve in growing swine [J].
Kuehne, T ;
Saeed, M ;
Reddy, G ;
Akbari, H ;
Gleason, K ;
Turner, D ;
Teitel, D ;
Moore, P ;
Higgins, CB .
CIRCULATION, 2001, 104 (19) :2363-2368
[9]   Coronary magnetic resonance angiography for assessment of the stent lumen: A phantom study [J].
Maintz, D ;
Botnar, RM ;
Fischbach, R ;
Heindel, W ;
Manning, WJ ;
Stuber, M .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (03) :359-367
[10]   MR evaluation of stent patency - In vitro tests of 22 metallic stents and the possibility of determining their patency by MR angiography [J].
Meyer, JMA ;
Buecker, A ;
Schuermann, K ;
Ruebben, A ;
Guenther, RW .
INVESTIGATIVE RADIOLOGY, 2000, 35 (12) :739-746