Algorithm for Thorough Background Subtraction of High-Resolution LC/MS Data: Application to Obtain Clean Product Ion Spectra from Nonselective Collision-Induced Dissociation Experiments

被引:22
作者
Zhang, Haiying [1 ]
Grubb, Mary [1 ]
Wu, Wei [2 ]
Josephs, Jonathan [1 ]
Humphreys, William G. [1 ]
机构
[1] Bristol Myers Squibb Res & Dev, Biotransformation, Pennington, NJ 08534 USA
[2] Bristol Myers Squibb Res & Dev, Prot Therapeut Dev, Pennington, NJ 08534 USA
关键词
TANDEM MASS-SPECTROMETRY; HEAVY-METAL TOXICITY; METABOLITE IDENTIFICATION; DRUG-METABOLISM; ELECTROSPRAY-IONIZATION; STRUCTURE ELUCIDATION; IN-VITRO; BUSPIRONE; TRAP; INDINAVIR;
D O I
10.1021/ac8027189
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nonselective collision-induced dissociation (CID) is a technique for producing fragmentation products for all ions generated in an ion source. It is typical of liquid chromatography/mass spectrometry (LC/MS) analysis of complex samples that matrix-related components may contribute to the resulting product ion spectra and confound the usefulness of this technique for structure interpretation. In this proof-of-principle study, a high-resolution LC/MS-based background subtraction algorithm was used to process the nonselective CID data to obtain clean product ion spectra for metabolites in human plasma samples. With buspirone and clozapine metabolites in human plasma as examples, this approach allowed for not only facile detection of metabolites of interest but also generation of their respective product ion spectra that were clean and free of matrix-related interferences. This was demonstrated with both an MS(E) technique (where E represents collision energy) with a quadrupole time-of-flight (QTOF) instrument and an in-source fragmentation technique with. an LTQ Orbitrap instrument. The combined nonselective CID and background subtraction approach should allow for detection and structural interpretation of other types of sample analyses where control samples are obtained.
引用
收藏
页码:2695 / 2700
页数:6
相关论文
共 36 条
[21]   Gas chromatography/mass spectrometry in metabolic profiling of biological fluids [J].
Pasikanti, Kishore K. ;
Ho, P. C. ;
Chan, E. C. Y. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :202-211
[22]   UPLC/MSE;: a new approach for generating molecular fragment information for biomarker structure elucidation [J].
Plumb, Robert S. ;
Johnson, Kelly A. ;
Rainville, Paul ;
Smith, Brian W. ;
Wilson, Ian D. ;
Castro-Perez, Jose M. ;
Nicholson, Jeremy K. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (13) :1989-1994
[23]   Ebrotidine and its metabolites studied by mass spectrometry with electrospray ionization. Comparison of tandem and in-source fragmentation [J].
Rozman, E ;
Galceran, MT ;
Albet, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (15) :1492-1498
[24]  
SETA K, 1996, KUROMATOGURAFI, V17, P344
[25]   Ion activation methods for tandem mass spectrometry [J].
Sleno, L ;
Volmer, DA .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (10) :1091-1112
[26]  
Tanaka K., 1988, RAPID COMMUN MASS SP, V2, P151, DOI [DOI 10.1002/RCM.1290020802, 10.1002/rcm.1290020802]
[27]   'All-in-One' analysis for metabolite identification using liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry with collision energy switching [J].
Wrona, M ;
Mauriala, T ;
Bateman, KP ;
Mortishire-Smith, RJ ;
O'Connor, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) :2597-2602
[28]   Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis [J].
Xia, YQ ;
Miller, JD ;
Bakhtiar, R ;
Franklin, RB ;
Liu, DQ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) :1137-1145
[29]   ELECTROSPRAY ION-SOURCE - ANOTHER VARIATION ON THE FREE-JET THEME [J].
YAMASHITA, M ;
FENN, JB .
JOURNAL OF PHYSICAL CHEMISTRY, 1984, 88 (20) :4451-4459
[30]   NEGATIVE-ION PRODUCTION WITH THE ELECTROSPRAY ION-SOURCE [J].
YAMASHITA, M ;
FENN, JB .
JOURNAL OF PHYSICAL CHEMISTRY, 1984, 88 (20) :4671-4675