Registration of electronic portal images for patient set-up verification

被引:21
作者
Matsopoulos, GK
Asvestas, PA
Delibasis, KK
Kouloulias, V
Uzunoglu, N
Karaiskos, P
Sandilos, P
机构
[1] Natl Tech Univ Athens, Inst Commun & Comp Syst, Athens 15780, Greece
[2] Hygeia Hosp, Dept Phys Med, Athens 15123, Greece
关键词
D O I
10.1088/0031-9155/49/14/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Images acquired from an electronic portal imaging device are aligned with digitally reconstructed radiographs (DRRs) or other portal images to verify patient positioning during radiation therapy. Most of the currently available computer aided registration methods are based on the manual placement of corresponding landmarks. The purpose of the paper is twofold: (a) the establishment of a methodology for patient set-up verification during radiotherapy based on the registration of electronic portal images, and (b) the evaluation of the proposed methodology in a clinical environment. The estimation of set-up errors, using the proposed methodology, can be accomplished by matching the portal image of the current fraction of the treatment with the portal image of the baseline treatment (reference portal image) using a nearly automated technique. The proposed registration method is tested on a number of phantom data as well as on data from four patients. The phantom data included portal images that corresponded to various positions of the phantom on the treatment couch. For each patient, a set of 30 portal images was used. For the phantom data (for both transverse and lateral portal images), the maximum absolute deviations of the translational shifts were within 1.5 mm, whereas the in-plane rotation angle error was less than 0.5degrees. The two-way Anova revealed no statistical significant variability both within observer and between-observer measurements (P > 0.05). For the patient data, the mean values obtained with manual and the proposed registration methods were within 0.5 mm. In conclusion, the proposed registration method has been incorporated within a system, called ESTERR-PRO. Its image registration capability achieves high accuracy and both intra- and inter-user reproducibility. The system is fully operational within the Radiotherapy Department of `HYGEIA' Hospital in Athens and it could be easily installed in any other clinical environment since it requires standardized hardware specifications and minimal human intervention.
引用
收藏
页码:3279 / 3289
页数:11
相关论文
共 26 条
[1]  
Armitage P., 2001, STAT METHODS MED RES, V4th
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]  
Bansal R, 1998, LECT NOTES COMPUT SC, V1496, P1075, DOI 10.1007/BFb0056297
[4]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[6]   Patient setup error measurement using 3D intensity-based image registration techniques [J].
Clippe, S ;
Sarrut, D ;
Malet, C ;
Miguet, S ;
Ginestet, C ;
Carrie, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :259-265
[7]   A portal image alignment and patient setup verification procedure using moments and correlation techniques [J].
Dong, L ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04) :697-723
[8]   An image correlation procedure for digitally reconstructed radiographs and electronic portal images [J].
Dong, L ;
Boyer, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1053-1060
[9]   Benchmark test cases for evaluation of computer-based methods for detection of setup errors: Realistic digitally reconstructed electronic portal images with known setup errors [J].
Fritsch, DS ;
Raghavan, S ;
Boxwala, A ;
Earnhart, J ;
Tracton, G ;
Cullip, T ;
Chaney, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :199-204
[10]   Core-based portal image registration for automatic radiotherapy treatment verification [J].
Fritsch, DS ;
Chaney, EL ;
Boxwala, A ;
McAuliffe, MJ ;
Raghavan, S ;
Thall, A ;
Earnhart, JRD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1287-1300