Dose distributions in SBRT of lung tumors:: Comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions

被引:53
作者
Lax, Ingmar [1 ]
Panettieri, Vanessa
Wennberg, Berit
Duch, Maria Amor
Naslund, Ingemar
Baumann, Pia
Gagliardi, Giovanna
机构
[1] Karolinska Univ Hosp, Dept Hosp Phys, S-17176 Stockholm, Sweden
[2] Karolinska Inst, Stockholm, Sweden
[3] Univ Politecn Catalunya, Inst Tecn Energet, Barcelona, Spain
[4] Karolinska Univ Hosp, Dept Oncol, S-17176 Stockholm, Sweden
关键词
D O I
10.1080/02841860600900050
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In stereotactic body radiotherapy (SBRT) of lung tumors, dosimetric problems arise from: 1) the limited accuracy in the dose calculation algorithms in treatment planning systems, and 2) the motions with the respiration of the tumor during treatment. Longitudinal dose distributions have been calculated with Monte Carlo simulation (MC), a pencil beam algorithm (PB) and a collapsed cone algorithm (CC) for two spherical lung tumors (2 cm and 5 cm diameter) in lung tissue, in a phantom situation. Respiratory motions were included by a convolution method, which was validated. In the static situation, the PB significantly overestimates the dose, relative to MC, while the CC gives a relatively accurate estimate. Four different respiratory motion patterns were included in the dose calculation with the MC. A "narrowing'' of the longitudinal dose profile of up to 20 mm (at about 90% dose level) is seen relative the static dose profile calculated with the PB.
引用
收藏
页码:978 / 988
页数:11
相关论文
共 14 条
[1]  
[Anonymous], STEREOTACTIC BODY RA
[2]   MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems [J].
Badano, A ;
Sempau, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :1545-1561
[3]   A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error [J].
Beckham, WA ;
Keall, PJ ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) :3465-3473
[4]   Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung [J].
Chetty, IJ ;
Rosu, M ;
McShan, DL ;
Fraass, BA ;
Balter, JM ;
Ten Haken, RK .
MEDICAL PHYSICS, 2004, 31 (04) :925-932
[5]   Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Rosenzweig, KE ;
Wagman, R ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (02) :522-531
[6]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[7]   The application of the sinusoidal model to lung cancer patient respiratory motion [J].
George, R ;
Vedam, SS ;
Chung, TD ;
Ramakrishnan, V ;
Keall, PJ .
MEDICAL PHYSICS, 2005, 32 (09) :2850-2861
[8]   STEREOTAXIC RADIOTHERAPY OF MALIGNANCIES IN THE ABDOMEN - METHODOLOGICAL ASPECTS [J].
LAX, I ;
BLOMGREN, H ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1994, 33 (06) :677-683
[9]   TARGET DOSE VERSUS EXTRATARGET DOSE IN STEREOTAXIC RADIOSURGERY [J].
LAX, I .
ACTA ONCOLOGICA, 1993, 32 (04) :453-457
[10]  
LAX I, 1998, J RADIOSURG, V1, P63