Purpose The aim of this article is to propose a diagnostic and therapeutic algorithm for the acetabular periprosthetic fractures. Methods This article explores the current literature on the epidemiology, causes and classification of periprosthetic acetabular fractures. Integrating data with the experience of the authors, it offers a guide to diagnosis and possible therapeutic strategies. Results Intra-operative fractures can occur during rasping, reaming or implant impaction, and they must be treated immediately if the component(s) is (are) unstable. Post-operative fractures can be due to major trauma (acute fractures) or minor forces in bone osteolysis; it is possible to plan reconstruction and fixation according to fracture characteristics. Treatment choice depends upon fracture site and implant stability. Conclusions Periprosthetic acetabular fractures are uncommon complications that can occur intra-operatively or post-operatively, and a reconstructive surgeon must be able to manage the procedure. Accurate planning and reconstruction implant are necessary to achieve good cup stability.
引用
收藏
页码:1959 / 1963
页数:5
相关论文
共 24 条
[11]
Traumatic periprosthetic acetabular fracture: life threatening haemorrhage and a novel method of acetabular reconstruction [J].
Harvie, P ;
Gundle, R ;
Willett, K .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (08) :819-822
[12]
FRACTURE OF THE ACETABULUM DURING INSERTION OF AN OVERSIZED HEMISPHERICAL COMPONENT [J].
KIM, YS ;
CALLAGHAN, JJ ;
AHN, PB ;
BROWN, TD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (01) :111-117
[13]
An oblong revision cup for large acetabular defects -: Design rationale and two- to seven-year follow-up [J].
Köster, G ;
Willert, HG ;
Köhler, HP ;
Döpkens, K .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :559-569
[14]
Periprosthetic Fractures of the Acetabulum During Cup Insertion: Posterior Column Stability is Crucial [J].
Laflamme, G-Yves ;
Belzile, Etienne L. ;
Fernandes, Julio C. ;
Vendittoli, Pascal A. ;
Hebert-Davies, Jonah .
JOURNAL OF ARTHROPLASTY, 2015, 30 (02) :265-269
[15]
Lww, 2009, ROCKWOOD GREENS FRAC, P348
[16]
McGrory B J, 1999, Am J Orthop (Belle Mead NJ), V28, P248
[17]
Miller A J, 1972, J Bone Joint Surg Br, V54, P600
[18]
The treatment of pelvic disconitinluity with acetabular cages [J].
Paprosky, Wayne ;
Sporer, Scott ;
O'Rourke, Michael R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :183-187
[19]
Periprosthetic fracture of the acetabulum after total hip arthroplasty [J].
Peterson, CA ;
Lewallen, DG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08) :1206-1213
[20]
The Reconstruction of Periprosthetic Pelvic Discontinuity [J].
Rogers, Benedict A. ;
Whittingham-Jones, Paul M. ;
Mitchell, Philip A. ;
Safir, Oleg A. ;
Bircher, Martin D. ;
Gross, Allan E. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (08) :1499-1506