Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples

被引:47
作者
Baldo, MA [1 ]
Daniele, S [1 ]
机构
[1] Univ Venice, Dept Chem Phys, I-30123 Venice, Italy
关键词
bismuth-coated microdisk electrode; carbon microdisk electrode; anodic stripping voltammetry; trace metals; food analysis;
D O I
10.1081/AL-120030293
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports on the Performance of a bismuth-coated carbon microdisk electrode (BiFmuE) for the determination of trace heavy metals by anodic stripping voltammetry (ASV). The BiFmuE was prepared by electrodeposition of a metallic bismuth film onto the microdisk, by applying an in-situ electroplating procedure. To test the performance of the BiFmuE, ASV measurements were performed on synthetic solutions containing Cd2+, Pb2+, and Cu2+ as target ions. The results indicated that cadmium and lead gave well-defined ASV peaks with no interference, and their quantitative determination could be carried out straightforwardly. In particular, linear calibration curves over the range 5.0 x 10(-8)-1.0 x 10(-6) M for both ions, and detection limits of 7.8 and 2.9 nM, for cadmium and lead, respectively, after applying a 60 see preconcentration step, were obtained. The reproducibility was also satisfactory, the relative standard deviation (RSD) being within 2.5% for both ions. Copper, instead, gave an ASV response that, in most experimental conditions, overlapped with that of bismuth. This circumstance made the determination of copper at the BiFmuE difficult. Since the latter element could be detected reliably at the uncoated carbon microdisk electrode (CmuE), both BiFmuE and CmuE were employed, respectively, for the determination of lead and copper ions in drinking water, wine, and tomato sauce.
引用
收藏
页码:995 / 1011
页数:17
相关论文
共 31 条
[11]  
Hocevar SB, 2002, ELECTROANAL, V14, P112, DOI 10.1002/1521-4109(200201)14:2<112::AID-ELAN112>3.0.CO
[12]  
2-5
[13]   An introduction to bismuth film electrode for use in cathodic electrochemical detection [J].
Hutton, EA ;
Ogorevc, B ;
Hocevar, SB ;
Weldon, F ;
Smyth, MR ;
Wang, J .
ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (12) :707-711
[14]   Bismuth film electrode for simultaneous adsorptive stripping analysis of trace cobalt and nickel using constant current chronopotentiometric and voltammetric protocol [J].
Hutton, EA ;
Hocevar, SB ;
Ogorevc, B ;
Smyth, MR .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (09) :765-769
[15]   Bismuth-film-plated carbon paste electrodes [J].
Królicka, A ;
Pauliukaite, R ;
Svancara, I ;
Metelka, R ;
Bobrowski, A ;
Norkus, E ;
Kalcher, K ;
Vytras, K .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (02) :193-196
[16]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[17]   Carbon paste electrodes modified with Bi2O3 sensors for the determination of Cd and Pb [J].
Pauliukaite, R ;
Metelka, R ;
Svancara, I ;
Królicka, A ;
Bobrowski, A ;
Vytras, K ;
Norkus, E ;
Kalcher, K .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (06) :1155-1158
[18]  
PLETCHER D, 1991, NATO ASI SER, P463
[19]  
SCHARIFKER B, 1981, J ELECTROANAL CHEM, V130, P81, DOI 10.1016/S0022-0728(81)80378-6
[20]   INSITU VOLTAMMETRIC MEASUREMENTS IN NATURAL-WATERS - FUTURE-PROSPECTS AND CHALLENGES [J].
TERCIER, ML ;
BUFFLE, J .
ELECTROANALYSIS, 1993, 5 (03) :187-200