Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode

被引:105
作者
Karimi-Maleh, H. [1 ]
Ensafi, A. A. [1 ]
Allafchian, A. R. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Ferrocenedicarboxylic acid; Captopril; Electrocatalysis; Carbon paste electrode; PERFORMANCE LIQUID-CHROMATOGRAPHY; ADSORPTIVE STRIPPING VOLTAMMETRY; SOLID-PHASE EXTRACTION; INJECTION-ANALYSIS; CAPILLARY-ELECTROPHORESIS; IMPEDANCE SPECTROSCOPY; THIOLS; DERIVATIZATION; HYDROCHLOROTHIAZIDE; DISULFIDES;
D O I
10.1007/s10008-008-0781-2
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A ferrocenedicarboxylic acid modified carbon paste electrode was constructed and used as a fast and sensitive tool for the determination of captopril at trace level. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that ferrocenedicarboxylic acid can catalyze the oxidation of captopril in aqueous buffer solution and produces a sharp oxidation peak current at about +0.49 vs. Ag/AgCl reference electrode. The square wave voltammetric peak currents of the electrode increased linearly with the corresponding captopril concentration in the range of 3.0 x 10(-7)-1.4 x 10(-4)M with a detection limit of 9.1 x 10(-8) M. The influence of pH and potential interfering substances on the determination of captopril were studied. Electrochemical impedance spectroscopy was used to study the charge transfer properties at the electrode-solution interface. Finally, the sensor was examined as a selective, simple, and precise new electrochemical sensor for the determination of captopril in real samples, such as drug and urine, with satisfactory results.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 39 条
[21]   Reflections on the history of electrochemical impedance spectroscopy [J].
Macdonald, DD .
ELECTROCHIMICA ACTA, 2006, 51 (8-9) :1376-1388
[22]  
Miller JN., 2000, STAT CHEMOMETRICS AN, V4th
[23]   Determination of captopril in pharmaceutical tablets by anion-exchange HPLC using indirect photometric detection; a study in systematic method development [J].
Mirza, T ;
Tan, HSI .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (01) :39-52
[24]   Chemiluminescence-based liquid chromatographic determination of hydrochlorothiazide and captopril [J].
Ouyang, J ;
Baeyens, WRG ;
Delanghe, J ;
Van Der Weken, G ;
Van Daele, W ;
De Keukeleire, D ;
Campaña, AMG .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :257-264
[25]   Impedance spectroscopy at interfaces of metals and aqueous solutions - Surface roughness, CPE and related issues [J].
Pajkossy, T .
SOLID STATE IONICS, 2005, 176 (25-28) :1997-2003
[26]   Square-wave voltammetric (SWV) determination of Captopril in reconstituted serum and pharmaceutical formulations [J].
Parham, H ;
Zargar, B .
TALANTA, 2005, 65 (03) :776-780
[27]   Sequential injection analysis of captopril based on colorimetric and potentiometric detection [J].
Pimenta, AM ;
Araújo, AN ;
Montenegro, MCBSM .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :31-38
[28]   L-cysteine voltammetry at a carbon paste electrode bulk-modified with ferrocenedicarboxylic acid [J].
Raoof, Jahan-Bakhsh ;
Ojani, Reza ;
Beitollahi, Hadi .
ELECTROANALYSIS, 2007, 19 (17) :1822-1830
[29]   Speciation and quantitation of underivatized and Ellman's derivatized biological thiols and disulfides by capillary electrophoresis [J].
Russell, J ;
Rabenstein, DL .
ANALYTICAL BIOCHEMISTRY, 1996, 242 (01) :136-144
[30]   HPLC determination of biologically active thiols using pre-column derivatisation with 5,5'-dithio-(bis-2-nitrobenzoic acid) [J].
Russell, J ;
McKeown, JA ;
Hensman, C ;
Smith, WE ;
Reglinski, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (11) :1757-1763