On the de-noising of Monte Carlo calculated dose distributions

被引:45
作者
Kawrakow, I [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1088/0031-9155/47/17/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an algorithm for de-noising Monte Carlo calculated dose distributions for use in radiation treatment planning. The algorithm is a three-dimensional generalization of a Savitzky-Golay digital filter and uses an adaptive smoothing window size to reduce the probability for systematic bias. The paper also introduces five accuracy criteria that are relevant for the expected clinical use of Monte Carlo techniques, which can be used to evaluate the performance of smoothing algorithms. Using these accuracy criteria it is demonstrated that the smoothing algorithm presented here decreases the uncertainty of Monte Carlo calculated dose distributions. The corresponding decrease in necessary particle tracks ranges from a factor of 2 to a factor of 20, depending on the accuracy criterion used. It is shown that very short Monte Carlo simulations combined with smoothing deliver satisfactory dose distributions-and may therefore be extremely valuable:for the initial trial and error phase of the radiation treatment planning process.
引用
收藏
页码:3087 / 3103
页数:17
相关论文
共 16 条
[1]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[2]   Monte Carlo dose calculations and radiobiological modelling: analysis of the effect of the statistical noise of the dose distribution on the probability of tumour control [J].
Buffa, FM ;
Nahum, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :3009-3023
[3]   Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques [J].
Deasy, JO .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07) :1765-1779
[4]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[5]   Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations [J].
Jiang, SB ;
Pawlicki, T ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2151-2161
[6]   Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC [J].
Kawrakow, I ;
Fippel, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2163-2183
[7]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[8]  
Kawrakow I, 2001, ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, P229
[9]   The effect of dose calculation uncertainty on the evaluation of radiotherapy plans [J].
Keall, PJ ;
Siebers, JV ;
Jeraj, R ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (03) :478-484
[10]  
Ma CM, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P123