Electrochemical immunoassays

被引:214
作者
Warsinke, A [1 ]
Benkert, A [1 ]
Scheller, FW [1 ]
机构
[1] Univ Potsdam, Inst Biochem & Mol Physiol, D-14943 Luckenwalde, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 6-7期
关键词
D O I
10.1007/s002160051557
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immunoassays (IA) use the specific antigen antibody complexation for analytical purposes. Radioimmunoassays (RIA), fluorescence immunoassays (FIA) and enzyme immunoassays (EIA) are well established in clinical diagnostics. For the development of hand-held devices which can be used for point of care measurements, electrochemical immunoassays are promising alternatives to existing immunochemical tests. Moreover, for opaque or optically dense matrices electrochemical methods are superior Potentiometric, capacitive and amperometric transducers have been applied for direct and indirect electrochemical immunoassays. However, due to their first detection, broad linear range and low detection limit, amperometric transducers are preferred. Competitive and noncompetitive amperometric immunoassays have been developed with odor compounds or enzymes as labels This review will give an overview of the most frequently applied principles in electrochemical immunoassays. The potential of an indirect competitive amperometric immunoassay for the determination of creatinine within nanomolar range and the circumvention of the most serious problem in electrochemical immunoassays, namely regeneration, will be discussed.
引用
收藏
页码:622 / 634
页数:13
相关论文
共 105 条
  • [81] PULSED AMPEROMETRIC DETECTION OF THAUMATIN USING ANTIBODY-CONTAINING POLY(PYRROLE) ELECTRODES
    SADIK, OA
    JOHN, MJ
    WALLACE, GG
    BARNETT, D
    CLARKE, C
    LAING, DG
    [J]. ANALYST, 1994, 119 (09) : 1997 - 2000
  • [82] Determination of β-HCG using amperometric immunosensors based on a conducting immunocomposite
    Santandreu, M
    Alegret, S
    Fàbregas, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) : 181 - 188
  • [83] Pulsed electrochemical technique for monitoring antibody-antigen reactions at interfaces
    Sargent, A
    Sadik, OA
    [J]. ANALYTICA CHIMICA ACTA, 1998, 376 (01) : 125 - 131
  • [84] SCHELLER FW, IN PRESS
  • [85] Reversible oriented surface immobilization of functional proteins on oxide surfaces
    Schmid, EL
    Keller, TA
    Dienes, Z
    Vogel, H
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 1979 - 1985
  • [86] SELF CH, Patent No. 803034784
  • [87] β-lactamase label-based potentiometric biosensor for α-2 interferon detection
    Sergeyeva, TA
    Soldatkin, AP
    Rachkov, AE
    Tereschenko, MI
    Piletsky, SA
    El'skaya, AV
    [J]. ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 73 - 81
  • [88] Ligand-induced domain movement in an antibody Fab: Molecular dynamics studies confirm the unique domain movement observed experimentally for Fab NC6.8 upon complexation and reveal its segmental flexibility
    Sotriffer, CA
    Liedl, KR
    Linthicum, DS
    Rode, BM
    Varga, JM
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 1998, 278 (02) : 301 - 306
  • [89] ANTIGEN-INDUCED CONFORMATIONAL-CHANGES IN ANTIBODIES - A PROBLEM FOR STRUCTURAL PREDICTION AND DESIGN
    STANFIELD, RL
    WILSON, IA
    [J]. TRENDS IN BIOTECHNOLOGY, 1994, 12 (07) : 275 - 279
  • [90] P-AMINOPHENYL PHOSPHATE - AN IMPROVED SUBSTRATE FOR ELECTROCHEMICAL ENZYME-IMMUNOASSAY
    TANG, HT
    LUNTE, CE
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) : 187 - 195