Isotope-ratio detection for gas chromatography

被引:214
作者
Sessions, Alex L. [1 ]
机构
[1] CALTECH, Div Geol & Planetary Sci, Pasadena, CA 91125 USA
关键词
combustion interface; compound-specific isotope analysis; GC-isotope-ratio mass spectrometry; isotope-ratio-monitoring; pyrolysis interface;
D O I
10.1002/jssc.200600002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Instrumentation and methods exist for highly precise analyses of the stable-isotopic composition of organic compounds separated by GC. The general approach combines a conventional GC, a chemical reaction interface, and a specialized isotoperatio mass spectrometer (IRMS). Most existing GC hardware and methods are amenable to isotope-ratio detection. The interface continuously and quantitatively converts all organic matter, including column bleed, to a common molecular form for isotopic measurement. C and N are analyzed as CO2 and N-2, respectively, derived from combustion of analytes. H and O are analyzed as H-2 and CO produced by pyrolysis/reduction. IRMS instruments are optimized to provide intense, highly stable ion beams, with extremely high precision realized via a system of differential measurements in which ion currents for all major isotopologs are simultaneously monitored. Calibration to an internationally recognized scale is achieved through comparison of closely spaced sample and standard peaks. Such systems are capable of measuring C-13/C-12 ratios with a precision approaching 0.1 parts per thousand (for values reported in the standard delta notation), four orders of magnitude better than that typically achieved by conventional "organic" mass spectrometers. Detection limits to achieve this level of precision are typically < 1 nmol C (roughly 10 ng of a typical hydrocarbon) injected on-column. Achievable precision and detection limits are correspondingly higher for N, O, and H, in that order.
引用
收藏
页码:1946 / 1961
页数:16
相关论文
共 98 条
[31]   Hyphenation of gas chromatographic techniques with isotope ratio mass spectrometry: Present status and future [J].
Douthitt, CB .
ANALUSIS, 1999, 27 (03) :197-199
[32]   Analytical improvements in irm-GC/MS analyses: Advanced techniques in tube furnace design and sample preparation [J].
Ellis, L ;
Fincannon, AL .
ORGANIC GEOCHEMISTRY, 1998, 29 (5-7) :1101-1117
[33]   EVIDENCE FROM CARBON ISOTOPE MEASUREMENTS FOR DIVERSE ORIGINS OF SEDIMENTARY HYDROCARBONS [J].
FREEMAN, KH ;
HAYES, JM ;
TRENDEL, JM ;
ALBRECHT, P .
NATURE, 1990, 343 (6255) :254-256
[34]   DEUTERIUM CONTENT OF NATURAL WATERS AND OTHER SUBSTANCES [J].
FRIEDMAN, I .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1953, 4 (1-2) :89-103
[35]   High-temperature elemental analysis and pyrolysis techniques for stable isotope analysis [J].
Gehre, M ;
Strauch, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (13) :1497-1503
[36]   Isotopes of volatile organic compounds: An emerging approach for studying atmospheric budgets and chemistry [J].
Goldstein, AH ;
Shaw, SL .
CHEMICAL REVIEWS, 2003, 103 (12) :5025-5048
[37]   HIGH-SENSITIVITY TRACER DETECTION USING HIGH-PRECISION GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY AND HIGHLY ENRICHED [U-C-13]-LABELED PRECURSORS [J].
GOODMAN, KJ ;
BRENNA, JT .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1088-1095
[38]   Hardware modifications to an isotope ratio mass spectrometer continuous-flow interface yielding improved signal, resolution, and maintenance [J].
Goodman, KJ .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :833-837
[39]   CURVE-FITTING FOR RESTORATION OF ACCURACY FOR OVERLAPPING PEAKS IN GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY [J].
GOODMAN, KJ ;
BRENNA, JT .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :1294-1301
[40]   HIGH-PRECISION GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY AT LOW SIGNAL LEVELS [J].
GOODMAN, KJ ;
BRENNA, JT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 689 (01) :63-68