Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps

被引:113
作者
Blain, MG
Riter, LS
Cruz, D
Austin, DE
Wu, GX
Plass, WR
Cooks, RG
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Univ Giessen, Phys Inst 2, D-35392 Giessen, Germany
关键词
cylindrical ion trap; miniature mass spectrometer; microlabrication; fieldable analytical instruments; simulations of ion motion;
D O I
10.1016/j.ijms.2004.06.011
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Breakthrough improvements in simplicity and reductions in the size of mass spectrometers are needed for high-consequence fieldable applications, including error-free detection of chemical/biological warfare agents, medical diagnoses, and explosives and contraband discovery. These improvements are most likely to be realized with the reconceptualization of the mass spectrometer, rather than by incremental steps towards miniaturization. Microfabricated arrays of mass analyzers represent such a conceptual advance. A massively parallel array of micrometer-scaled mass analyzers on a chip has the potential to set the performance standard for hand-held sensors due to the inherit selectivity, sensitivity, and universal applicability of mass spectrometry as an analytical method. While the effort to develop a complete micro-MS system must include innovations in ultra-small- scale sample introduction, ion sources, mass analyzers, detectors, and vacuum and power subsystems, the first step towards radical miniaturization lies in the design, fabrication, and characterization of the mass analyzer itself. In this paper we discuss design considerations and results from simulations of ion trapping behavior for a micrometer scale cylindrical ion trap (CIT) mass analyzer (internal radius r(0) = 1mum). We also present a description of the design and microfabrication of a 0.25 cm 2 array of 10(6) one-micrometer CITs, including integrated ion detectors, constructed in tungsten on a silicon substrate. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:91 / 104
页数:14
相关论文
共 54 条
  • [41] PRIETO MC, 1997, P 45 ASMS C MASS SPE
  • [42] RINGOES NJ, 2000, INT J MASS SPECTROM, V200, P3
  • [43] Analytical performance of a miniature cylindrical ion trap mass spectrometer
    Riter, LS
    Peng, YA
    Noll, RJ
    Patterson, GE
    Aggerholm, T
    Cooks, RG
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6154 - 6162
  • [44] Direct analysis of volatile organic compounds in human breath using a miniaturized cylindrical ion trap mass spectrometer with a membrane inlet
    Riter, LS
    Laughlin, BC
    Nikolaev, E
    Cooks, RG
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (24) : 2370 - 2373
  • [45] THE EVOLUTION OF INTERCONNECTION TECHNOLOGY AT IBM
    RYAN, JG
    GEFFKEN, RM
    POULIN, NR
    PARASZCZAK, JR
    [J]. IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1995, 39 (04) : 371 - 381
  • [46] A two-dimensional quadrupole ion trap mass spectrometer
    Schwartz, JC
    Senko, MW
    Syka, JEP
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (06) : 659 - 669
  • [47] Development of an underwater mass-spectrometry system for in situ chemical analysis
    Short, RT
    Fries, DP
    Toler, SK
    Lembke, CE
    Byrne, RH
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (12) : 1195 - 1201
  • [48] Micromachined mass spectrometer
    Sillon, N
    Baptist, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) : 129 - 137
  • [49] Sze SM, 1988, VLSI TECHNOLOGY
  • [50] High-throughput miniature cylindrical ion trap array mass spectrometer
    Tabert, AM
    Griep-Raming, J
    Guymon, AJ
    Cooks, RG
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (21) : 5656 - 5664