Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation

被引:165
作者
Cogan, SF
Guzelian, AA
Agnew, WF
Yuen, TGH
McCreery, DB
机构
[1] EIC Labs Inc, Norwood, MA 02062 USA
[2] Huntington Med Res Inst, Neural Engn Program, Pasadena, CA 91105 USA
关键词
iridium oxide films; electrodes; neural stimulation; cortex;
D O I
10.1016/j.jneumeth.2004.02.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microelectrodes using activated iridium oxide (AIROF) charge-injection coatings have been pulsed in cat cortex at levels from near-threshold for neural excitation to the reported in vitro electrochemical charge-injection limits of AIROF. The microelectrodes were subjected to continuous biphasic current pulsing, using an 0.4 V (versus Ag\AgC]) anodic bias with equal cathodal and anodal pulse widths, for periods up to 7 h at a frequency of either 50 Hz or 100 Hz. At charge densities of 3 mC/cm(2), histology revealed iridium-containing deposits in tissue adjacent to the charge-injection sites and scanning electron microscopy of explanted electrodes revealed a thickened and poorly adherent AIROF coating. Microelectrodes pulsed at 2 mC/cm(2) or less remained intact, with no histologic evidence of non-biologic deposits in the tissue. AIROF microelectrodes challenged in vitro under the same pulsing conditions responded similarly, with electrodes pulsed at 3 mC/cm(2) showing evidence of AIROF delamination after only 100 s of pulsing at 100 Hz (10,000 pulses total), while electrodes pulsed at 2 mC/cm(2) for 7 h at 50 Hz (1.3 x 106 pulses total) showed no evidence of damage. In vitro electrochemical potential transient measurements in buffered physiologic saline indicate that polarizing the AIROF beyond the potential window for electrolysis of water (-0.6 to 0.8 V versus AglAgC]) results in the observed degradation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 26 条
[21]  
Robblee L S, 1990, NEURAL PROSTHESES FU, P25
[22]   ACTIVATED IR - AN ELECTRODE SUITABLE FOR REVERSIBLE CHARGE INJECTION IN SALINE SOLUTION [J].
ROBBLEE, LS ;
LEFKO, JL ;
BRUMMER, SB .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (03) :731-733
[23]   ELECTRICAL-STIMULATION WITH PT ELECTRODES .8. ELECTROCHEMICALLY SAFE CHARGE INJECTION LIMITS WITH 0.2 MS PULSES [J].
ROSE, TL ;
ROBBLEE, LS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (11) :1118-1120
[24]   Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex [J].
Schmidt, EM ;
Bak, MJ ;
Hambrecht, FT ;
Kufta, CV ;
ORourke, DK ;
Vallabhanath, P .
BRAIN, 1996, 119 :507-522
[25]   In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes [J].
Weiland, JD ;
Anderson, DJ ;
Humayun, MS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (12) :1574-1579
[26]   Chronic neural stimulation with thin-film, iridium oxide electrodes [J].
Weiland, JD ;
Anderson, DJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (07) :911-918