Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation

被引:53
作者
Hubka, M
Bolson, EL
McDonald, JA
Martin, RW
Munt, B
Sheehan, FH [1 ]
机构
[1] Univ Washington, Cardiovasc Res & Training Ctr, Seattle, WA 98195 USA
[2] Univ Washington, Appl Phys Lab, Seattle, WA 98105 USA
[3] St Pauls Hosp, Cardiac Echo Lab, Vancouver, BC V6Z 1Y6, Canada
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2002年 / 18卷 / 02期
关键词
3D echo; LV; mass; RV; volume;
D O I
10.1023/A:1014616603301
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Three-dimensional (3D) echocardiography has been shown to offer highly accurate measurements of left ventricular (LV) volume and mass. The present study evaluated the accuracy of 3D surface reconstruction by the piecewise smooth subdivision method in measuring volume and mass not only in the LV but also in the more complexly shaped right ventricle (RV). Methods: 3D echo scans were obtained of in vitro LV's (n = 15) and RVs (n = 10). From digitized images, ventricular borders were traced and used in surface reconstructions. Mass and volume determined from the reconstructions were compared to true volume and mass determined prior to imaging. Additionally casts of two RVs were made and laser-scanned. Distances between the laser-identified points on the RV surface and the corresponding 3D echo reconstructions were measured. Results: 3D LV volume agreed well with the true volume (y = 0.99x + 1.73, r = 0.99, SEE = 3.35 ml, p < 0.0001), as did 3D LV mass (y = 0.99x - 4.71, r = 0.99, SEE = 9.85 g, p < 0.0001). 3D RV volume overestimated true volume (y = 1.11 x + 1.77, r = 0.99, SEE = 3.36 ml, p < 0.001) by 6.23 +/- 3.70 ml (p < 0.0001). 3D mass agreed well with RV mass (y = 0.78x + 17.32, r(2) = 0.93, SEE = 3.54 g, p < 0.0001). 3D echo reconstructions matched the laser-scanned RV closely with residual distances of 1.1 +/- 0.9 and 1.4 +/- 1.2 mm, respectively. Conclusions: 3D echo using freehand scanning combined with surface reconstruction by the piecewise smooth subdivision surface method enables accurate determination of LV mass and volume, of RV mass and volume, and of the RV's complex shape.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 15 条
[1]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[2]  
FILER EP, 1994, THESIS U WASHINGTON
[3]  
Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115
[4]   3-DIMENSIONAL ECHOCARDIOGRAPHY - IN-VITRO AND IN-VIVO VALIDATION OF LEFT-VENTRICULAR MASS AND COMPARISON WITH CONVENTIONAL ECHOCARDIOGRAPHIC METHODS [J].
GOPAL, AS ;
KELLER, AM ;
SHEN, ZQ ;
SAPIN, PM ;
SCHROEDER, KM ;
KING, DL ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :504-513
[5]  
Jiang L, 1994, J Am Soc Echocardiogr, V7, P150
[6]   QUANTITATIVE 3-DIMENSIONAL RECONSTRUCTION OF ANEURYSMAL LEFT-VENTRICLES - IN-VITRO AND IN-VIVO VALIDATION [J].
JIANG, L ;
DEPRADA, JAV ;
HANDSCHUMACHER, MD ;
VUILLE, C ;
GUERERRO, JL ;
PICARD, MH ;
JOZIATIS, JT ;
FALLON, JT ;
WEYMAN, AE ;
LEVINE, RA .
CIRCULATION, 1995, 91 (01) :222-230
[7]  
KING DL, 1991, J ULTRAS MED, V10, P77
[8]   System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing system [J].
Legget, ME ;
Leotta, DF ;
Bolson, EL ;
McDonald, JA ;
Martin, RW ;
Li, XN ;
Otto, CM ;
Sheehan, FH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (04) :494-504
[9]   Transthoracic three-dimensional echocardiographic reconstruction of left and right ventricles: In vitro validation and comparison with magnetic resonance imaging [J].
Pini, R ;
Giannazzo, G ;
DiBari, M ;
Innocenti, F ;
Rega, L ;
Casolo, G ;
Devereux, RB .
AMERICAN HEART JOURNAL, 1997, 133 (02) :221-229
[10]   3-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN-VITRO - COMPARISON WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
SAPIN, PM ;
SCHROEDER, KD ;
SMITH, MD ;
DEMARIA, AN ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1530-1537