Electrochemical estimation of the polyphenol index in wines using a laccase biosensor

被引:78
作者
Gamella, M. [1 ]
Campuzano, S. [1 ]
Reviejo, A. J. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
polyphenol index; laccase; amperometric biosensor; wines;
D O I
10.1021/jf061451r
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The use of a laccase biosensor, under both batch and flow injection (FI) conditions, for a rapid and reliable amperometric estimation of the total content of polyphenolic compounds in wines is reported. The enzyme was immobilized by cross-linking with glutaraldehyde onto a glassy carbon electrode. Caffeic acid and gallic acid were selected as standard compounds to carry out such estimation. Experimental variables such as the enzyme loading, the applied potential, and the pH value were optimized, and different aspects regarding the operational stability of the laccase biosensor were evaluated. Using batch amperometry at -200 mV, the detection limits obtained were 2.6 x 10(-3) and 7.2 x 10(-4) mg L-1 gallic acid and caffeic acid, respectively, which compares advantageously with previous biosensor designs. An extremely simple sample treatment consisting only of an appropriate dilution of wine sample with the supporting electrolyte solution (0.1 mol L-1 citrate buffer of pH 5.0) was needed for the amperometric analysis of red, rose, and white wines. Good correlations were found when the polyphenol indices obtained with the biosensor (in both the batch and FI modes) for different wine samples were plotted versus the results achieved with the classic Folin-Ciocalteu method. Application of the calibration transfer chemometric model (multiplicative fitting) allowed that the confidence intervals (for a significance level of 0.05) for the slope and intercept values of the amperometric index versus Folin-Ciocalteu index plots (r = 0.997) included the unit and zero values, respectively. This indicates that the laccase biosensor can be successfully used for the estimation of the polyphenol index in wines when compared with the Folin-Ciocalteu reference method.
引用
收藏
页码:7960 / 7967
页数:8
相关论文
共 37 条
[21]  
Jewell WT, 2001, AM J ENOL VITICULT, V52, P219
[22]   A cyclic voltammetry method suitable for characterizing antioxidant properties of wine and wine phenolics [J].
Kilmartin, PA ;
Zou, HL ;
Waterhouse, AL .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (04) :1957-1965
[23]   Synergic effect studies of the bi-enzymatic system laccase-peroxidase in a voltammetric biosensor for catecholamines [J].
Leite, OD ;
Lupetti, KO ;
Fatibello, O ;
Vieira, IC ;
Barbosa, AD .
TALANTA, 2003, 59 (05) :889-896
[24]   Autoanalyzer for continuous fractionation and quantitation of the polyphenols content in wines [J].
Lucena, R ;
Cárdenas, S ;
Gallego, M ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (02) :127-131
[25]   HRP-based amperometric biosensor for the polyphenols determination in vegetables extract [J].
Mello, LD ;
Sotomayor, MDPT ;
Kubota, LT .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) :636-645
[26]   Calibration transfer for solving the signal instability in quantitative headspace-mass spectrometry [J].
Pavón, JLP ;
Sánchez, MD ;
Pinto, CG ;
Laespada, MEF ;
Cordero, BM .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6361-6367
[27]   Amperometric detection of catechol and catecholamines by immobilized laccase from DeniLite [J].
Quan, D ;
Shin, W .
ELECTROANALYSIS, 2004, 16 (19) :1576-1582
[28]  
Quan D, 2002, B KOREAN CHEM SOC, V23, P385
[29]  
QUIMICA SAP, TECNICAS USUALES ANA
[30]   ADVANCES IN AMPEROMETRIC ENZYME ELECTRODES IN REVERSED MICELLES [J].
REVIEJO, AJ ;
FERNANDEZ, C ;
LIU, F ;
PINGARRON, JM ;
WANG, J .