Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies

被引:19
作者
Hammami, M
Koo, WWK
Hockman, EM
机构
[1] Wayne State Univ, Dept Pediat Obsted & Gynecol, Detroit, MI USA
[2] Wayne State Univ, Dept Comp & Informat Technol, Detroit, MI USA
关键词
D O I
10.1177/0148607104028005328
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: A piglet model was used to determine the influence of frequently encountered situations in clinical studies of infants and young children on fan-beam dual-energy x-ray absorptiometry (DXA) measurements. Methods: DXA scans of piglets (640 g to 21,100 g) were acquired in the infant and adult mode and were analyzed with 1 infant, 1 pediatric, and 3 versions of adult software. Results: The effect of repositioning of the piglets from the center to the periphery of the scanning table on DXA measurements included an average difference of up to 0.5% for total weight, 5.0% for bone mineral content, 5.6% for bone mineral density, 1.3% for lean mass, and 21.9% for fat mass (p less than or equal to .05, all comparisons) although no significant changes occurred when the piglets were scanned in symmetrical positions on either edge of the scanning table. Different posture (prone vs supine and side), varied number of blankets overlaid or wrapped around the piglet, and parenteral but not enteral bolus feeding could significantly alter fan-beam DXA measurements to varying extents. Adult and pediatric software underestimated bone area and bone mineral content but overestimated bone mineral density, lean mass, fat mass, and total weight compared with infant software measurements. However, strong predictive relationships among these fan-beam DXA data in subjects > 10 kg allow systematic corrections of data from different scan modes and different software. Conclusions: Attention to details and consistency in the technique for scan acquisition and analysis are critical to the generation of meaningful data and to allow for detection of true differences in DXA measurements of small subjects.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 11 条
[1]   Clinical applications of body composition measurements using DXA [J].
Albanese, CV ;
Diessel, E ;
Genant, HK .
JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (02) :75-85
[2]   Fan beam dual energy X-ray absorptiometry body composition measurements in piglets [J].
Chauhan, S ;
Koo, WWK ;
Hammami, M ;
Hockman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (05) :408-414
[3]   Neonatal body composition:: Dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets [J].
Fusch, C ;
Slotboom, J ;
Fuehrer, U ;
Schumacher, R ;
Keisker, A ;
Zimmermann, W ;
Moessinger, A ;
Boesch, C ;
Blum, J .
PEDIATRIC RESEARCH, 1999, 46 (04) :465-473
[4]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[5]  
Koo WWK, 2000, ANN NY ACAD SCI, V904, P383
[6]  
KOO WWK, 1995, J BONE MINER RES, V10, P1111
[7]   Dual energy X-ray absorptiometry measurements in small subjects: Conditions affecting clinical measurements [J].
Koo, WWK ;
Hockman, EM ;
Hammami, M .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2004, 23 (03) :212-219
[8]   Use of fan beam dual energy X-ray absorptiometry to measure body composition of piglets [J].
Koo, WWK ;
Hammami, M ;
Hockman, EM .
JOURNAL OF NUTRITION, 2002, 132 (06) :1380-1383
[9]  
KOO WWK, 1995, J BONE MINER RES, V10, P1998
[10]  
KOO WWK, IN PRESS J AM COLL N