Glow-discharge treated piezoelectric quartz crystals as immunosensors for HSA detection

被引:31
作者
Saber, R
Mutlu, S
Piskin, E [1 ]
机构
[1] Hacettepe Univ, Dept Chem Engn, TR-06532 Ankara, Turkey
[2] Hacettepe Univ, Bioengn Div, TR-06532 Ankara, Turkey
关键词
immunosensor; piezoelectric quartz crystal; glow-discharge; antibody immobilization; human serum albumin (HSA);
D O I
10.1016/S0956-5663(02)00058-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this study is to develop an immunoaffinity sensor based on piezoelectric crystals for human serum albumin (HSA) detection in aqueous media. Quartz crystals were treated with ethylene diamine (EDA) plasma in a glow-discharge apparatus in order to substitute amino groups on their surfaces. Then anti-HSA antibodies were immobilized via these amino groups by using glutaraldehyde (GA) as cross linker. Immobilization of the antibody on the quartz crystal was examined for different pH, antibody concentration and treatment time. The optimum conditions for anti-HSA immobilization were evaluated by the measurements of the activity of the surface against HSA. The optimum values of pH, antibody concentration and treatment time were found 6.2, 0.15 mg/ml and 2 h, respectively. For detection of HSA into the solution, two methods were used. In the first (dip and dry) method, the frequency shifts were measured in air after the 1 h interaction of the anti-HSA immobilized crystals with HSA solution. In the other (direct) method, the frequency shifts were followed continuously for 60 min. while the probe was immersed in the HSA solution. An increase for the frequency shifts was observed with increasing of HSA concentration of 16-128 mug/ml. Both the immobilization and antibody-interaction conditions were found important on the extend of these specific interaction. The relations between the HSA concentrations and frequency shifts were exponential in both methods. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:727 / 734
页数:8
相关论文
共 37 条
[21]   Piezoelectric immunosensors - Theory and applications [J].
O'Sullivan, CK ;
Vaughan, R ;
Guilbault, GG .
ANALYTICAL LETTERS, 1999, 32 (12) :2353-2377
[22]   Commercial quartz crystal microbalances - theory and applications [J].
O'Sullivan, CK ;
Guilbault, GG .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (8-9) :663-670
[23]   Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal [J].
Park, IS ;
Kim, N .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1091-1097
[24]   DEVELOPMENT OF A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF ENTEROBACTERIA [J].
PLOMER, M ;
GUILBAULT, GG ;
HOCK, B .
ENZYME AND MICROBIAL TECHNOLOGY, 1992, 14 (03) :230-235
[25]   DEVELOPMENT OF A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF SALMONELLA-TYPHIMURIUM [J].
PRUSAKSOCHACZEWSKI, E ;
LUONG, JHT ;
GUILBAULT, GG .
ENZYME AND MICROBIAL TECHNOLOGY, 1990, 12 (03) :173-177
[26]  
SABER R, 2001, THESIS HACETTEP U AN
[27]   VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG [J].
SAUERBREY, G .
ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02) :206-222
[28]   Capture agents for a quartz crystal microbalance-continuous flow biosensor: functionalized self-assembled monolayers on gold [J].
Spangler, BD ;
Tyler, BJ .
ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) :51-62
[29]   Chiral-discriminative amino acid films prepared by vacuum vaporization and/or plasma processing [J].
Sugimoto, I ;
Nakamura, M ;
Seyama, M ;
Ogawa, S ;
Katoh, T .
ANALYST, 2000, 125 (01) :169-174
[30]   Activating piezoelectric crystal surface by silanization for microgravimetric immunobiosensor application [J].
Suri, CR ;
Mishra, GC .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (12) :1199-1205