Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant?

被引:34
作者
Klotz, Stefan
Stypmann, Joerg
Welp, Henryk
Schmid, Christof
Drees, Gabriele
Rukosujew, Andreas
Scheld, Hans H.
机构
[1] Univ Hosp Munster, Dept Thorac & Cardiovasc Surg, D-48149 Munster, Germany
[2] Univ Hosp Munster, Dept Cardiol, D-48149 Munster, Germany
[3] Univ Hosp Munster, Dept Angiol, D-48149 Munster, Germany
关键词
D O I
10.1016/j.athoracsur.2006.05.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Left ventricular assist devices ( LVADs) with continuous flow properties are increasingly used to bridge heart failure patients to cardiac transplantation. Advantages in comparison with the pulsatile LVADs are smaller size, better endurance, and lower thromboembolic events. However, whether these new pumps have similar pre- and posttransplant outcomes is not clear. Methods. Fifty patients with a continuous flow device (Micromed DeBakey, Houston, TX or InCor BerlinHeart, Berlin, Germany) were compared with an age-, disease-, and LVAD duration-matched control group (n = 80) supported with a pulsatile device (Novacor, WorldHeart, Oakland, CA or HeartMate, Thoratec Corp, Pleasanton, CA). Results. Age (44.3 +/- 13.4 vs 46.1 +/- 11.1 years), disease ( idiopathic dilated cardiomyopathy, 58% vs 65%), and LVAD duration (138 +/- 131 vs 128 +/- 106 days) were comparable in both groups. Successful bridging to transplantation was similar with continuous flow in comparison with pulsatile device support (52% vs 56%, p = not significant [NS]). Thirty-day mortality after cardiac transplantation in patients with continuous flow LVAD support was 21.7% vs 22.2% with pulsatile LVADs (p = NS). Reasons for death were similar among the different LVAD groups. Long-term survival was similar in both LVAD groups compared with patients without previous LVAD support. Interestingly, severe rejections were significantly more frequent in patients with a continuous flow LVAD (p < 0.001). Conclusions. The new generation of cardiac assist devices with continuous flow pattern has a similar rate of pre- and posttransplant mortality in comparison with pulsatile LVADs. However, the rate and severity of posttransplant rejection was significantly higher in the group with continuous flow devices. Further studies are warranted to explain the higher rate of severe rejections.
引用
收藏
页码:1774 / 1778
页数:5
相关论文
共 29 条
[1]   A miniature implantable axial flow ventricular assist device [J].
DeBakey, ME .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :637-640
[2]   Effect of mechanical circulatory support on outcomes after heart transplantation [J].
Drakos, SG ;
Kfoury, AG ;
Long, JW ;
Stringham, JC ;
Gilbert, EM ;
Moore, SA ;
Campbell, BK ;
Nelson, KE ;
Horne, BD ;
Renlund, DG .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (01) :22-28
[3]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[4]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[5]   Human leukocyte antigen sensitization in ventricular assist device recipients: A lesser risk with the DeBakey axial pump [J].
Grinda, JM ;
Bricourt, MO ;
Arnrein, C ;
Salvi, S ;
Guillemain, R ;
Francois, A ;
Guibourt, P ;
Deloche, A ;
Fabiani, JN .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :945-949
[6]   Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device [J].
Hetzer, R ;
Müller, J ;
Weng, YG ;
Wallukat, G ;
Spiegelsberger, S ;
Loebe, M .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :742-749
[7]  
Hetzer R, 2002, HERZ, V27, P407, DOI 10.1007/s00059-002-2400-9
[8]   Impact of current management practices on early and late death in move than 500 consecutive cardiac transplant recipients [J].
John, R ;
Rajasinghe, H ;
Chen, JM ;
Weinberg, AD ;
Sinha, P ;
Itescu, S ;
Lietz, K ;
Mancini, D ;
Oz, MC ;
Smith, CR ;
Rose, EA ;
Edwards, NM .
ANNALS OF SURGERY, 2000, 232 (03) :302-310
[9]   Impact of left venticular assist device (LVAD)-mediated humoral sensitization on post-transplant outcomes [J].
Joyce, DL ;
Southard, RE ;
Torre-Amione, G ;
Noon, GP ;
Land, GA ;
Loebe, M .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (12) :2054-2059
[10]   Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support [J].
Klotz, S ;
Deng, MC ;
Stypmann, J ;
Roetker, J ;
Wilhelm, MJ ;
Hammel, D ;
Scheld, HH ;
Schmid, C .
ANNALS OF THORACIC SURGERY, 2004, 77 (01) :143-149