Analysis of cytokinin nucleotides in coconut (Cocos nucifera L.) water using capillary zone electrophoresis-tandem mass spectrometry after solid-phase extraction

被引:41
作者
Ge, Liya
Yong, Jean Wan Hong
Tan, Swee Ngin
Yang, Xin Hao
Ong, Eng Shi
机构
[1] Nanyang Technol Univ, Nat Sci & Sci Educ Acad Grp, Singapore 637616, Singapore
[2] Singapore Epson Ind Pte Ltd, Dept Engn, Plating Div, Singapore 628162, Singapore
[3] Natl Univ Singapore, Yong Loo Ling Sch Med, Dept Community Occupat & Family Med, Singapore 117597, Singapore
关键词
capillary zone electrophoresis; tandem mass spectrometry; cytokinin nucleotide; solid-phase extraction; coconut water;
D O I
10.1016/j.chroma.2006.08.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is described for the separation and determination of six cytokinin nucleotides in coconut water. The best CZE separation for the six cytokinin nucleotide standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) methanol with an applied gradient separation voltage (25 kV for 32 min, and then a linear gradient to 30 kV in 5 min, finally 30 kV to the end of separation) in less than 60 min. MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity and sensitivity for the cytokinin nucleotides. The combined use of on-line sample stacking and CZE-MS/MS achieved limits of detection (LODs) in the range of 0.06-0.19 mu M for the six cytokinin nucleotides at a signal-to-noise ratio of 3. Furthermore, a novel dual-step SPE procedure was developed for the pre-concentration and purification of cytokinin nucleotides using Oasis HLB and Oasis MAX cartridges. The recoveries of the cytokinin nucleotides after the dual-step SPE were in the range of 44-71%. The combination of off-line SPE, on-line sample stacking and CZE-MS/MS approach was successfully applied to screen for endogenous cytokinin nucleotides present in coconut water sample. trans-Zeatin riboside-5'-monophosphate (ZMP) was detected and quantified in coconut water by CZE-MS/MS after SPE and on-line sample stacking. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:322 / 331
页数:10
相关论文
共 43 条
[1]   A protocol for in vitro germination and sustainable growth of two tropical mistletoes [J].
Ang, SLP ;
Yong, JWH .
PLANT CELL TISSUE AND ORGAN CULTURE, 2005, 80 (02) :221-228
[2]  
Anurag P., 2003, Plant Foods Hum. Nutr, V58, P1, DOI DOI 10.1023/B:QUAL.0000040363.64356.05
[3]  
Arditti J., 1993, MICROPROPAGATION ORC, P47
[4]  
Åstot C, 1998, J MASS SPECTROM, V33, P892, DOI 10.1002/(SICI)1096-9888(199809)33:9<892::AID-JMS701>3.0.CO
[5]  
2-N
[6]   Determination of nicotine and its metabolites in urine by solid-phase extraction and sample stacking capillary electrophoresis-mass spectrometry [J].
Baidoo, EEK ;
Clench, MR ;
Smith, RF ;
Tetler, LW .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02) :303-313
[7]   The intravenous use of coconut water [J].
Campbell-Falck, D ;
Thomas, T ;
Falck, TM ;
Tutuo, N ;
Clem, K .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (01) :108-111
[8]   Automated instrumentation for comprehensive isotachophoresis-capillary zone electrophoresis [J].
Chen, SJ ;
Lee, ML .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :816-820
[9]  
Dobrev PI, 2002, J CHROMATOGR A, V950, P21, DOI 10.1016/S0021-9673(02)00024-9
[10]   Determination of triazine compounds in ground water samples by micellar electrokinetic capillary chromatography [J].
Frías, S ;
Sánchez, MJ ;
Rodríguez, MA .
ANALYTICA CHIMICA ACTA, 2004, 503 (02) :271-278