Low-dose nuclear microscopy as a necessity for accurate quantitative microanalysis of biological samples

被引:17
作者
Maetz, M
Przybylowicz, WJ
Mesjasz-Przybylowicz, J
Schüssler, A
Traxel, K
机构
[1] Max Planck Inst Kernphys, D-69029 Heidelberg, Germany
[2] Natl Accelerator Ctr, Van de Graaff Grp, ZA-7131 Faure, South Africa
[3] Tech Univ Darmstadt, Inst Bot, D-64287 Darmstadt, Germany
[4] Univ Heidelberg, Inst Phys, D-69120 Heidelberg, Germany
关键词
STIM; biology; PIXE; accuracy; damage;
D O I
10.1016/S0168-583X(99)00331-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Some aspects of quantitative analysis of biological samples - including a review of the relevant literature - are discussed, Special emphasis is put on the accuracy of trace elemental results despite severe sample damage which occurs during analysis. The occuring mass loss can be corrected by combining quantitative STIM and PIXE. It is also possible to characterize the volatility of most of the minor and trace elements of the sample. The comparison between the presented model and matrix determination with RES, a widely used method, definitely demonstrates that the concentrations obtained using RES correction only may be too high by a factor of two. We recommend at least one low-dose analysis to do correct quantification, (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 30 条
[1]   CONTROL OF TEMPERATURE IN THIN SAMPLES DURING ION-BEAM ANALYSIS [J].
CAHILL, TA ;
MCCOLM, DW ;
KUSKO, BH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (01) :38-44
[2]   TEMPERATURE ESTIMATION OF ORGANIC FOIL FOR PARTICLE BEAMS [J].
CHOLEWA, M ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :651-654
[3]   CHANGES IN ORGANIC MATERIALS WITH SCANNING PARTICLE MICROBEAMS [J].
CHOLEWA, M ;
BENCH, G ;
KIRBY, BJ ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3) :101-108
[4]  
Chu W., 1978, BACKSCATTERING SPECT, DOI DOI 10.1016/B978-0-12-173850-1.50008-9
[5]   SPECIMEN DAMAGE BY NUCLEAR MICROBEAMS AND ITS AVOIDANCE [J].
COOKSON, JA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 30 (03) :324-330
[6]   APPLICATION OF A PROTON MICROPROBE TO BIOMEDICAL-RESEARCH - LIMITS AND POTENTIALITIES [J].
GONSIOR, B ;
BISCHOF, W ;
HOFERT, M ;
RAITH, B ;
STRATMANN, A ;
ROKITA, E .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1987, 12 :33-44
[7]  
Johansson S.A.E., 1995, PARTICLE INDUCED XRA
[8]   ION-BEAM INDUCED DAMAGE AND ELEMENT LOSS DURING A MICROANALYSIS OF BIOLOGICAL TISSUE [J].
KIRBY, BJ ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3) :98-100
[9]   ELEMENTAL MICROANALYSIS OF BIOLOGICAL AND MEDICAL SPECIMENS WITH A SCANNING PROTON MICROPROBE [J].
LEGGE, GJF ;
MAZZOLINI, AP .
NUCLEAR INSTRUMENTS & METHODS, 1980, 168 (1-3) :563-569
[10]   ADVANTAGES OF HIGH-SPEED SCANNING FOR MICROPROBE ANALYSIS OF BIOLOGICAL SAMPLES [J].
LLABADOR, Y ;
BERTAULT, D ;
GOUILLAUD, JC ;
MORETTO, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4) :435-440