Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode

被引:50
作者
Milardovic, S [1 ]
Kruhak, I [1 ]
Ivekovic, D [1 ]
Rumenjak, V [1 ]
Tkalcec, M [1 ]
Grabaric, BS [1 ]
机构
[1] UNIV ZAGREB,FAC MED,CLIN DEPT,DIAGNOST LAB,HR-10000 ZAGREB,CROATIA
关键词
amperometric glucose biosensor; clinical application; blood glucose analysis; flow injection analysis; chronoamperometry;
D O I
10.1016/S0003-2670(97)00308-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple amperometric enzyme-based glucose sensor is applied as detector in flow injection analysis (FIA) of diabetic patients blood glucose. The enzyme glucose oxidase (GOD) is immobilized by a glutaraldehyde/bovine serum albumin crosslinking procedure on the surface of an alkali nickel hexacyanoferrate thin film electrocrystallized on the nickel electrode. An alkali nickel hexacyanoferrate modified nickel electrode catalyzes the reduction of the hydrogen peroxide, formed by selective biocatalytic GOD action on glucose oxidation by oxygen present in sample solutions. The developed glucose sensor has shown good sensitivity at low negative operating potentials (-300 to -100 mV vs. Ag/AgCl), sufficiently wide linear glucose concentration range (5 mu M-2.9 mM), relatively long operating time (during three months of operation the initial sensitivity decreased only 30%) and no influence of the most common interferences present in human blood like proteins, ascorbic and uric acids.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 38 条
[1]   DEVELOPMENT OF A NEEDLE TYPE GLUCOSE BIOSENSOR [J].
ABDELHAMID, I ;
ATANASOV, P ;
WILKINS, E .
ANALYTICAL LETTERS, 1994, 27 (08) :1453-1473
[2]   DEVELOPMENT OF A NEEDLE-TYPE BIOSENSOR FOR INTRAVASCULAR GLUCOSE MONITORING [J].
ABDELHAMID, I ;
ATANASOV, P ;
WILKINS, E .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :45-54
[3]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[4]   AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ .
TALANTA, 1991, 38 (01) :107-110
[5]   THE SLOW PENETRATION OF ENZYME-BASED BIOSENSORS INTO CLINICAL-CHEMISTRY ANALYSIS [J].
CHRISTIANSEN, TF ;
JAKOBSEN, KM .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 :31-35
[6]  
CSOREGI E, 1995, ANAL CHEM, V67, P1240
[7]  
FIELD S, 1964, ELECTROPLATING, P296
[8]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[9]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[10]   CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS [J].
GUNASINGHAM, H ;
TAN, CH .
ANALYST, 1990, 115 (01) :35-39