Ultrahigh resolution Fourier domain optical coherence tomography

被引:333
作者
Leitgeb, RA
Drexler, W
Unterhuber, A
Hermann, B
Bajraszewski, T
Le, T
Stingl, A
Fercher, AF
机构
[1] Med Univ Vienna, Dept Med Phys, A-1090 Vienna, Austria
[2] Med Univ Vienna, Christian Doppler Lab, A-1090 Vienna, Austria
[3] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[4] Femolaser Prod GmbH, A-1100 Vienna, Austria
来源
OPTICS EXPRESS | 2004年 / 12卷 / 10期
关键词
D O I
10.1364/OPEX.12.002156
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present, for the first time, in vivo ultrahigh resolution (similar to2.5 mum in tissue), high speed (10000 A-scans/second equivalent acquisition rate sustained over 160 A-scans) retinal imaging obtained with Fourier domain (FD) OCT employing a commercially available, compact (500x260mm), broad bandwidth (120 nm at full-width-at-half-maximum centered at 800 nm) Titanium: sapphire laser (Femtosource Integral OCT, Femtolasers Produktions GmbH). Resolution and sampling requirements, dispersion compensation as well as dynamic range for ultrahigh resolution FD OCT are carefully analyzed. In vivo OCT sensitivity performance achieved by ultrahigh resolution FD OCT was similar to that of ultrahigh resolution time domain OCT, although employing only 2-3 times less optical power (similar to300 muW). Visualization of intra-retinal layers, especially the inner and outer segment of the photoreceptor layer, obtained by FDOCT was comparable to that, accomplished by ultrahigh resolution time domain OCT, despite an at least 40 times higher data acquisition speed of FD OCT. (C) 2004 Optical Society of America.
引用
收藏
页码:2156 / 2165
页数:10
相关论文
共 21 条
[1]   Optical coherence tomography by "spectral radar":: Improvement of signal-to-noise ratio [J].
Andretzky, P ;
Knauer, M ;
Kiesewetter, F ;
Häusler, G .
COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 :55-59
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Sattmarin, H ;
Hermann, B ;
Ko, TH ;
Stur, M ;
Unterhuber, A ;
Scholda, C ;
Findl, O ;
Wirtitsch, M ;
Fujimoto, JG ;
Fercher, AF .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (05) :695-706
[5]   Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[6]  
DREXLER W, 2004, SPIE P, V5214, P5214
[7]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[8]   Dispersion effects in partial coherence interferometry: Implications for intraocular ranging [J].
Hitzenberger, CK ;
Baumgartner, A ;
Drexler, W ;
Fercher, AF .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :144-151
[9]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894